Table of Contents:

  • Page 3 – Contents
  • Page 5 – Safety; Symbols used in this guide; Indicates important information.
  • Page 6 – Installation safety; EPO
  • Page 7 – System Overview; UPS Sections; Serial number
  • Page 8 – Configurations; Configuration 1 (Inverter Section placed to the left); in; Control Section
  • Page 9 – Configuration 2 (Inverter Section placed to the right); Inverter Section
  • Page 10 – External Bypass Static Switch
  • Page 11 – Electrical Installation; Typical UPS Wiring Principle; Power wiring overview
  • Page 12 – External disconnection switches
  • Page 13 – Top Cable Entry; Cable entry in top cover of Input/Output Section.; Top view
  • Page 14 – Battery cable connections (top cable entry); Refer to the battery manufacturer’s installation manual.; BAT 1 and BAT 2 cables MUST be run in separate conduits.
  • Page 15 – Feed the battery cables through the top of Input/Output Section.; Top view of Input/Output Section
  • Page 16 – Ground and AC cable connections (top cable entry); Connect the cables as illustrated.
  • Page 17 – Bottom Cable Entry; Preparing for bottom cable entry; Cable entry in bottom cover of Input/Output Section; Front view
  • Page 19 – Battery cable connections (bottom cable entry)
  • Page 20 – Connect cables from battery system as illustrated.
  • Page 21 – Ground and AC cable connections (bottom cable entry); Connect cables as illustrated.
  • Page 22 – Bypass Static Switch Wiring
  • Page 23 – Top cable entry; Loosen the 8 bolts to remove top cover.; No drilling or cutting should take place over the top of the UPS.; PE
  • Page 24 – Bottom cable entry; Loosen the 8 bolts to remove bottom cover.; No drilling or cutting should take place inside the UPS.; Top view of bottom cable entry
  • Page 25 – Communication cable overview; Contact APC Application Team for correct
  • Page 26 – Location of optional Relay Board
  • Page 27 – Communication cables with optional Relay Board
  • Page 28 – Relay Board functions; Name
  • Page 31 – Specifications; The Symmetra; Low-impedance grounding; Grounding electrode conductor to be supplied by the customer.
  • Page 33 – Electrical Specification; Installation Planning Data; Maintenance Bypass Panel; UPS
  • Page 34 – DC Input; DC Input
  • Page 35 – raceways. Cables shall be rated at 600 V as a minimum.; AC Output; AC Input External Bypass SSW
  • Page 36 – Section III of the 2002 NEC.
  • Page 38 – Torque specifications; Cable lugs are not supplied.
  • Page 39 – Required Breaker Settings; Input and upstream breakers — minimum settings; * Only applicable to Q1; * Only applicable to Q2 and Q4
  • Page 40 – Dual Utility Installation
  • Page 41 – General Specifications 480 V
  • Page 42 – APC Worldwide Customer Support
Loading the manual

Installation

Symmetra

®

MW

1000 kW

480 V

~

~

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Contents

Contents Symmetra MW 1000 kW 480 V Installation - 990-4112E i Safety ......................................................................1 IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Symbols used in this guide . . . . . . . . . . . ...

Page 5 - Safety; Symbols used in this guide; Indicates important information.

Symmetra MW 1000 kW 480 V Installation - 990-4112E 1 Safety IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS This guide contains important instructions for SYMF1000KG that should be followed when handling the UPS, External Bypass Static Switch, Battery Enclosures, and Batteries. Symbols used ...

Page 6 - Installation safety; EPO

Safety: IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 2 Symmetra MW 1000 kW 480 V Installation - 990-4112E Installation safety Press the EPO (Emergency Power Off) button to switch off all AC and DC power supply to connected equipment in the room. The EPO is typically located on a wall in t...