APC MW II - Manual

APC MW II

APC MW II – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 3 – Contents
  • Page 5 – Safety; IMPORTANT SAFETY INSTRUCTIONS; Symbols used in this guide; Indicates important information.; Installation safety; breakers are in the open position.; EPO
  • Page 6 – circuits in the units.; start without any warning when power is applied.
  • Page 7 – System Overview; UPS Sections; Serial number; Inverter Section
  • Page 8 – External Bypass Static Switch; MW External Bypass Static Switch
  • Page 9 – Electrical Installation; Typical UPS Wiring Principle; Power wiring overview
  • Page 10 – Use only copper conductors.
  • Page 11 – AC and PE cable connections; No drilling or cutting should take place over the top of the UPS.
  • Page 12 – Battery cables connection; manufacturer’s installation manual.
  • Page 13 – The battery cables can be connected on either side of the busbar.
  • Page 14 – External Bypass Static Switch Wiring; national regulations.
  • Page 15 – Top cable entry; Loosen the 8 bolts to remove top cover.; Top view of top cover
  • Page 16 – Communication cable overview; Contact APC Application Team for correct
  • Page 17 – Relay Boards; Location of relay boards; Relay boards
  • Page 18 – Relay board 1 connections; Relay
  • Page 19 – Relay board 2 connections
  • Page 21 – Specifications; The Symmetra; Electrical Specifications; Max. prospective RMS short-circuit current on DC terminals: 50 kA
  • Page 22 – AC Input; Input Voltage; DC Input
  • Page 23 – AC Output; AC Input External Bypass SSW
  • Page 24 – Required Breaker Settings (400 V Systems); Input and upstream breakers; Torque specifications
  • Page 25 – Output and downstream breakers; replaced by a link with an infinitely small impedance
  • Page 26 – and breaker frame sizes.
  • Page 27 – Appendix; System and Protective Earthing; Characteristics; part of the system
  • Page 28 – Protective devices in TN systems; The following protective devices are recognized in TN systems:
  • Page 29 – TT Systems
  • Page 30 – IT Systems
  • Page 31 – Protective devices in IT systems
  • Page 40 – APC Worldwide Customer Support; Global support searching APC Knowledge Base and using e-support.; Customer Support Center by telephone or e-mail.
Loading the manual

Installation

Symmetra

®

MW II

1200 kW

400 V

X022

X021

X007

X010

X011

X008B

X008A

X012

X013

X014A

X014B

X017

X405

~

~

Normal

UPS Summary

Normal

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Contents

Contents Symmetra MW II 1200 kW 3 x 400/230 V Installation - 990-1979E-001 i Safety ......................................................................1 IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Symbols used in this guide . . . ....

Page 5 - Safety; IMPORTANT SAFETY INSTRUCTIONS; Symbols used in this guide; Indicates important information.; Installation safety; breakers are in the open position.; EPO

1 Symmetra MW II 1200 kW 3 x 400/230 V Installation - 990-1979E-001 Safety IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS This guide contains important instructions for SYMF1200KH that should be followed when handling the UPS, External Bypass Static Switch, Battery Enclosures, and Batteries...

Page 6 - circuits in the units.; start without any warning when power is applied.

Symmetra MW II 1200 kW 3 x 400/230 V Installation - 990-1979E-001 2 Warning: Do not use high voltage testing equipment as it will destroy the electronic circuits in the units. Caution: The system is equipped with an optional auto-start function enabling the system to start without any warning when p...