Thank You! Thank you for selecting the APC MasterSwitch VM (vertical-mount) power distribution unit ( PDU ). It has been designed for many years of reliable, maintenance-freeservice. APC is dedicated to the development of high- performance electrical power conversion and controlproducts. We hope tha...
Page 3 - Contents; Quick Configuration
i Contents Preliminary Information . . . . . . . . . . . . . . . . . . . . . 1 Features of MasterSwitch VM 1 Inventory 2 Please recycle 2 Installing MasterSwitch VM . . . . . . . . . . . . . . . . . . 3 Mounting in a NetShelter enclosure 3 Mounting the controller 5 Hardwiring procedure 7 Connecting ...
Page 5 - Preliminary Information; Continued on next page
1 Preliminary Information Features ofMasterSwitch VM American Power Conversion’s MasterSwitch VM is a vertically-mounted, stand-alone, network-manageable powerdistribution unit ( PDU ) designed to accommodate a total of 16 outlets: eight individually-managed outlets and eight always-on outlets. You ...
Page 6 - Inventory; unit
2 Preliminary Information continued Inventory MasterSwitch VM ( AP9221X166 ) comes with the following items: Please recycle The shipping materials for MasterSwitch VM are recyclable. Please save them for later reuse or dispose of themappropriately. Item Part Number Quantity MasterSwitch VM unit AP92...
Page 7 - Installing MasterSwitch VM; APC; NetShelter enclosure or other standard; Note; : To avoid interfering with shelves or equipment, install
3 Installing MasterSwitch VM Mounting in aNetShelterenclosure MasterSwitch VM comes with rack-mount brackets formounting in an APC NetShelter enclosure or other standard ( EIA310-D ) 19 -inch rack. To mount in an enclosure: 1. Align the brackets (provided) with the holes on the rear of the unit. 2. ...
Page 8 - Insert a caged nut above and below a notched hole on a
4 Installing MasterSwitch VM continued Mounting in aNetShelterenclosure,continued 4. Insert a caged nut above and below a notched hole on a vertical mounting rail at the highest point in your chosenlocation. 5. Align the mounting holes of the top bracket on the unit with the caged nuts you installed...
Page 10 - Insert caged nuts on the vertical mounting rails at your
6 Installing MasterSwitch VM continued Mounting thecontroller,continued 3. Insert caged nuts on the vertical mounting rails at your chosen location. 4. Align the controller’s brackets with the caged nuts that you inserted in Step 3. 5. Insert mounting screws (provided with enclosure) and tighten. Co...
Page 12 - Connecting MasterSwitch VM; Caution
8 Connecting MasterSwitch VM Caution MasterSwitch VM does not provide power protection. Therefore, APC does not recommend plugging the unit directly into any unprotected power source, such as a wall outlet. Setting up asingle unit 1. Connect the power cord of each device you wish to connect to the o...
Page 14 - User Guide
10 Quick Configuration Requiredconfiguration You must configure the network settings of MasterSwitch VM before it can operate on a network. The required settings are: • IP address of MasterSwitch VM • Subnet Mask• IP address of the default Gateway After you have configured MasterSwitch VM network se...
Page 15 - Through the Management Card Wizard.; Serially through the Control Console.; plus; UNIX
11 Quick Configuration continued ConfiguringTCP/IP settings,continued Through the Management Card Wizard. The MasterSwitch VM controller contains a management card that provides the network interface. The Management Card Wizard provides aquick way to configure all management card settings, including...
Page 16 - apc; Logout; BOOTP
12 Quick Configuration continued ConfiguringTCP/IP settings,continued 6. Enter the default user name and password: apc , both lowercase. 7. Once the Main menu appears, choose Network. 8. From the Network menu, choose TCP/IP . 9. Within the TCP/IP menu: a. Disable BOOTP b. Accept changes. c. Set a va...
Page 17 - Over the Network by ARP.; ARP; telnet
13 Quick Configuration continued ConfiguringTCP/IP settings,continued Over the Network by ARP. (Address Resolution Protocol) To configure MasterSwitch VM TCP/IP settings using ARP : 1. Connect the unit to the network. 2. From a command prompt on a computer connected to the local subnet, type arp -s ...
Page 18 - Through a Web browser.
14 Quick Configuration continued AccessingMasterSwitchVM You can access MasterSwitch VM using a Web browser, Telnet, or SNMP . See the appropriate paragraph below for details. Through a Web browser. 1. From your Web browser, enter the System IP address or DNS name, if configured, of the MasterSwitch...
Page 20 - APC Worldwide Customer Support; Submit customer support requests.; Latin America
APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of thefollowing ways: • Visit the APC Web site to find answers to frequently asked questions (FAQs), toaccess documents in the APC Knowledge Base, and to submit customer supportrequests...