Table of Contents:

  • Page 2 – Use compression type lugs ONLY.; Single mains; Connect the DC Battery Cables; Warning
  • Page 3 – EPO wiring – pin connections J108.; Connect APC communication options; Front panel removal.; : Dry Contacts Normally Closed; XR battery enclosure
  • Page 4 – Specifications; The UPS must be supplied from a 380/220 V,; AC input
  • Page 5 – At 100% switch mode load, the neutral must; Minimum breaker settings
  • Page 6 – Wiring diagrams; Diagram with Maintenance
Loading the manual

990-2258B-001

9/2009

*990-2258B-

Installation

MGE™ Galaxy™ 3500

10-40 kVA 380/400/415 V with batteries

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Warning:

ALL safety instructions in the Safety Sheet

(990-2940) must be read, understood, and followed when
installing the UPS system. Failure to do so could result in
equipment damage, serious injury, or death.

Warning:

After the UPS has been electrically wired, do

not start it up. Start-up is commissioned to authorized
personnel from Schneider Electric.

Caution:

All electrical power and power control wiring

must be installed by a qualified electrician, and must comply
with local and national regulations for maximum power
rating.

Note:

Ensure that the unit is in its final location prior to

installation.

Note:

Battery and utility/mains power must not be

connected until all other wiring has been completed.

See Also:

For parallel configurations see manual 990-

3568.

Level the Enclosure

Warning:

The system must be installed on a level floor.

The leveling feet will stabilize the enclosure, but will not
account for a badly sloped floor.

Use a 13/14 mm wrench to adjust the four leveling feet.

Ensure that the system is level.

Caution:

Do not move the enclosure after the leveling feet

have been lowered.

Floor Anchoring (if applicable)

Anchor the UPS enclosure to the floor

Note:

Floor-anchoring bolts are not provided with the UPS.

Purchase the bolts locally (minimum size: M8). Follow the
specifications given by the manufacturer of the floor
anchoring system when bolting the UPS system to the floor.

Reuse the two transport brackets (one

on each side) that were used to secure the
UPS to the pallet during transport.

Drill two to six holes in the floor for

each bracket. Attach with bolts.

Prepare for Cables

Bottom cable entry

From the rear of the UPS, loosen the six

M4 screws from the upper cover (the cable
landing area) on the back and remove.

Route the cables from the

slanted back plate, up
through the punched
bracket, and into the cable
landing area.

Fasten the cables with

cable ties

Note:

A conduit box (part no. SUVTOPT001 or

SUVTOPT002) is available as an option.

UPS

UPS

XR battery enclosure

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Use compression type lugs ONLY.; Single mains; Connect the DC Battery Cables; Warning

2 Connect the AC Input and AC Output Cables Warning: Use compression type lugs ONLY. Do not loosen or add cables to any factory preinstalled cables on busbars. Use the front part of busbar for connection only. See Also: For different grounding configurations please see manual 990-3606 . Single mains...

Page 3 - EPO wiring – pin connections J108.; Connect APC communication options; Front panel removal.; : Dry Contacts Normally Closed; XR battery enclosure

3 EPO wiring – pin connections J108. Connect the EPO cable using one of the following four wiring configurations. Pin connections J106 (UPS). Note: When connecting the Q3 auxiliary signal, use gold- plated N/C auxiliary switch. Note: Reinstall the cable landing cover. Connect APC communication optio...

Page 4 - Specifications; The UPS must be supplied from a 380/220 V,; AC input

4  Remove the two screws from the cable-inlet at the front and remove the cable-inlet plate.  Guide the cable through the hole in the bottom plate and up through the cable- inlet.  Guide the cable through the side panel hole and run the cable upwards inside the panel.  Pull the cable out of the ...

Other APC Models

All APC Other