A.O. Smith BFC - 100 - Manual

A.O. Smith BFC - 100

A.O. Smith BFC - 100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – Technical specifications; Draw-off capacity; Electrical data
  • Page 3 – Dimensions
  • Page 4 – Installation diagrams
  • Page 5 – Electrical diagram BFC 28-60
  • Page 6 – Installation options; Minimum space requirements
Loading the manual

Innovation has a name.

Cyclone BFC

Condensing Glass-Lined
Water Heater

BFC - 28/30/50/60/80/100

Fully room-sealed condensing high-effi ciency water heater (95%gross)
• Flexible fl ue options (maximum length 115 m) allows installation
almost anywhere • ThermoControl for easy fl exible control/fault
diagnosis • Meets latest EPC standards: Cyclone BFC 28-60: 0.902
• Utilises premix Low-NOx burner BFC 80/100 • Patented Cyclone
burner BFC28-60 • All models suitable for natural or LP gas
• Programmable for legionella purge cycle • Scale formation is
reduced through the improved design and location of the heat
exchanger • Cyclone BFC 80/100: comes as standard with powered
anodes to reduce maintenance requirements • Remote control
connection • Voltage-free contact for general fault indication
• Optional ancillaries: Unvented kits • Destratifi cation pump kit
• Powered anodes

Meets

EPC

standards

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Technical specifications; Draw-off capacity; Electrical data

Cyclone BFC Technical specifications Gas data natural gas 2H (G20) Input* kW 32.1 34.5 52.6 63.2 86.6 105.5 Output kW 30.5 32.7 48.8 59.6 81.9 99.8 Inlet pressure mbar 20 20 20 20 20 20 Burner pressure mbar 8.5 8.5 8.5 11.5 7.0 6.0 Gas consumption** m 3 /h 3.1 3.3 5.0 6.0 8.3 10.1 Diameter main orif...

Page 3 - Dimensions

BFC 80-100 BFC 28-60 Cyclone BFC Dimensions A 1390 1910 1910 1910 2060 2060 C - - - - 530 530 D 705 705 705 705 850 850 E - - - - 1000 1000 F - - - - 900 900 G 80/125 100/150 100/150 100/150 130/200 130/200H 1365 1905 1905 1905 2015 2015 Hx 265 265 265 265 310 310 Hy 375 375 375 375 440 440 K 1270 1...

Page 4 - Installation diagrams

Vented Unvented 1 Pressure reducing valve3 T&P valve4 Stop valve5 Non-return valve6 Circulation pump9 Drain valve10 Gas cock11 Isolating valve12 Temperature gauge13 Condense drain 14 Hot water outlets15 Expansion relief valve16 Expansion vessel17 Three way valve18 Water tank19 Float valve A Cold...