A.O. Smith AO-MF - User Manual

A.O. Smith AO-MF

A.O. Smith AO-MF Water Filter – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

NSF/ANSI 401

Maximum Concentration

Minimum Reduction Overall % Reduction Results

Microplastics

(particles 0.5 to <1 μm)

At least 10,000 particles/mL

97.3%

99.4%

Pass

Filter is only to be used
with cold water.

Click here to view the system’s warranty.

Performance Data Sheet for the A. O. Smith Direct Connect Filter

Models

Replacement

Rated capacity

Operating temp. range

Rated flow

Operating Pressure range

AO-MF

AO-MF-R

1,389 gallons

5,258 liters

40-90° F

4.44-32.2° C

1.4 gpm

5.3 lpm

10 to 125 psi

68.9-861 kPa

Manufactured by: A. O. Smith Corporation

| 11270 W Park Pl #170, Milwaukee, WI 53224 | 877.333.7108

NSF/ANSI 42

Minimum Reduction

Overall % Reduction

Results

Chlorine Reduction, Free Available

97.5%

97.5%

Pass

Particulate Reduction I

97.3%

99.4%

Pass

NSF/ANSI 53

Minimum Reduction

Overall % Reduction

Results

Atrazine

89.1%

93.7%

Pass

Cyst Live Cryptosporidium & Giardia

>99.99%

>99.99%

Pass

Lead Reduction pH 6.5

5 ug/L

>99.3%

Pass

Lead Reduction pH 8.5

5 ug/L

>99.3%

Pass

Lindane

97.4%

98.8%

Pass

Turbidity

0.5 NTU

98.7%

Pass

System and certified by IAPMO R&T against NSF/ANSI Standards

42, 53, and 401 for the reduction of the claims specified on the

Performance Data Sheet and at www.IAPMO.org.

• All contaminants reduced by this filter are listed.

• Not all contaminants listed may be present in your water.

• Does not remove all contaminants that may be present in tap water.

• The contaminants covered in NSF/ANSI 401 have been deemed as incidental/emerging compounds and have been detected in drinking water supplies at trace levels.

These compounds can affect some consumers’ perception of drinking water quality.

• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

This system has been tested according to NSF/ANSI Standards 42, 53, and 401 for reduction of the substances listed below. The concentration of the

indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as

specified in NSF/ANSI Standards 42, 53, and 401.

Testing was performed under standard laboratory
conditions, actual performance may vary.

Systems certified for cyst reduction may be
used on disinfected waters that may contain
filterable cysts.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other A.O. Smith Water Filters Models