A.O. Smith 401 - Manual
A.O. Smith 401 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – DIMENSIONS/CAPACITIES DATA; TABLE 2. DIMENSIONAL DATA
- Page 3 – DIMENSIONS DATA FOR OUTDOOR CONFIGURATION; TABLE 3. DIMENSIONAL DATA
- Page 4 – FOREWORD; GB MODELS-FLOW, HEAD LOSS AND TEMPERATURE RISE
- Page 5 – and/or local codes. The boiler is polarity sensitive, correct; WARNING
- Page 6 – CAUTION; An adjustable automatic reset limit control, that can be set; Do not operate this boiler using the internal; , the circulator is NOT provided and
- Page 7 – INSTALLATION INSTRUCTIONS; REQUIRED ABILITY; • THE BOILER MUST NOT BE INSTALLED ON CARPETING.
- Page 8 – Observing proper clearances will allow service to
- Page 9 – /kW) of the total input of all appliances in the; VENTING; THE BOILER VENT COLLAR.; THIS BOILER MAY BE VENTED ACCORDING TO TABLE 10 (ALSO
- Page 10 – HORIZONTAL VENT INSTALLATION
- Page 11 – Figure 5. Vent Termination Installation Clearances; INTAKE /EXHAUST INSTALLATION REQUIREMENTS; SYSTEM INSTALLATION; GENERAL
- Page 12 – VENT PRESSURE MUST BE MAINTAINED
- Page 15 – safety and health of inhabitants.
- Page 16 – HYDRONIC INSTALLATION; TABLE 14: INSTALLATION ITEMS
- Page 17 – Figure 10. Single or Multiple Boiler Installation Diagram
- Page 18 – WATER LINE CONNECTIONS
- Page 19 – ONE GENESIS (MODEL GW) HOT WATER SUPPLY BOILER WITH HORIZONTAL TANK; DANGER; Figure 11. Single boiler with horizontal tank.
- Page 20 – ONE GENESIS (MODEL GW) HOT WATER SUPPLY BOILER WITH VERTICAL TANK; Figure 13. Single boiler with vertical tank.
- Page 21 – ABLE 16. Suggested Pipe Size For Multiple Gas
- Page 22 – WIRING CONNECTIONS; Make the
- Page 23 – GAS MANIFOLD ASSEMBLY
- Page 26 – TIC DIAGRAM
- Page 31 – OPERATION; FILLING AND PURGING WATER SYSTEM
- Page 32 – Lighting Instructions for the G(B/W) 1000 through 2500 models; FOR YOUR SAFETY READ BEFORE OPERATING
- Page 34 – CONTROL SYSTEM; CAUTION: The internal communications cables should; MANIFOLD PRESSURE; ADJUSTMENTS
- Page 36 – cycled on and off to accept the change.
- Page 37 – Operating Sequence
- Page 38 – Temperature Setpoints (System Control Algorithm); FIGURE 20 A. FIGURE 20 B.; UIM OPERATING PROCEDURES
- Page 39 – System Status Screen
- Page 40 – Description of FCB control states:
- Page 41 – OPERATING SETPOINT ADJUSTMENT PROCEDURE
- Page 42 – TROUBLESHOOTING IGNITION SYSTEM; Same as above. Also try swapping FCB and UIM communications cables.
- Page 44 – PREVENTATIVE MAINTENANCE; MAIN BURNERS
- Page 45 – RELIEF VALVE; COMBUSTION AIR FILTER; The blower compartment should be cleaned annually to remove; VENTING MAINTENANCE; HEAT EXCHANGER PREVENTIVE MAINTENANCE
- Page 46 – F (3°C) in the normal temperature rise through; TUBE CLEANING PROCEDURE; Note: Removal of the heat exchanger is not required.; When ordering parts
- Page 47 – NEW BOILER LIMITED WARRANTY
1
PRINTED IN U.S.A. 0906
COPPER BOILERS FOR
HYDRONIC HEATING AND
HOT WATER SUPPLY
CAUTION
TEXT PRINTED OR OUTLINED IN RED CONTAINS
I N F O R M AT I O N R E L AT I V E TO Y O U R S A F E T Y.
PLEASE READ THOROUGHLY BEFORE INSTALLING
AND USING THIS APPLIANCE.
212511-000
MC BEE, SC., RENTON, WA.,
STRATFORD-ONTARIO, VELDHOVEN-THE NETHERLANDS,
NANJING, CHINA
www.hotwater.com / email:[email protected]
PLACE THESE INSTRUCTIONS ADJACENT TO BOILER AND
NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.
•
Installation
•
Operation
•
Maintenance
•
Limited Warranty
Instruction Manual
GB/GW
MODELS
:
1000, 1300, 1500, 1850, 2100, 2500
SERIES: 400, 401, 402, 403, 404, 405
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
Thank Y
ou
for buying this cost
efficient, high recovery unit from
A. O. Smith Water Products Co.
You should thoroughly read and understand this
manual before installation and/or operation of this
b o i l e r. P l e a s e pa y pa r t i c u l a r a t t e n t i o n t o t h e
important safety and operating instructions as well
as the WARNINGS and CAUTIONS.
CONTENTS
PAGE
DIMENSIONS/CAPACITIES DATA .......................... 2 - 3
FOREWORD ......................................................... 4 - 5
FEATURES/CONTROLS ..................................... 5 - 7
INSTALLATION INSTRUCTIONS ....................... 7 - 9
VENTING ........................................................... 9 - 11
SYSTEM INSTALLATION ................................ 11 - 16
HYDRONIC INSTALLATION ............................ 16 - 18
HOT WATER SUPPLY INSTALLATION ........... 18 - 31
GAS CONNECTIONS ...................................... 18 - 23
OPERATION .................................................... 31 - 34
LIGHTING AND OPERATING .......................... 32 - 33
CONTROL SYSTEM ....................................... 34 - 44
PREVENTATIVE MAINTENANCE .................. 44 - 46
TROUBLE SHOOTING .................................... 42 - 44
WIRING DIAGRAM/SCHEMATIC ................... 24 - 27
LIMITED WARRANTY ............................................. 47
•
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
•
Extinguish any open flame.
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do
not use any phone in your building.
•
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
•
If you cannot reach your gas supplier,
call the fire department.
•
I n s t a l l a t i o n a n d s e r v i c e m u s t b e
performed by a qualified installer,
service agency or the gas supplier.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 DIMENSIONS/CAPACITIES DATA Figure 1. IMPORTANT! Refer to "Installation Clearances" section of manual(page 7) for recommended service clearances priorto boiler placement. TOP VIEW LEFT SIDE TABLE 2. DIMENSIONAL DATA A B C D E F M o d e l I n c h e s c m I n c h e s c m I n c h e s c m I n c...
3 DIMENSIONS DATA FOR OUTDOOR CONFIGURATION Figure 2. TABLE 3. DIMENSIONAL DATA A B C D E F G H J Model Inches cm Inches cm Inches cm Inches cm Inches cm Inches cm Inches cm Inches cm Inches cm GBO/GWO-1000 14 35.5 31.6 80.3 71.8 182.4 15.5 39.4 39.75 101 58.25 148 15.9 40.83 16 40.64 46.8 118.9 GBO...
4 TABLE 5: PUMPING PERFORMANCE GUIDE TABLE 4: RECOVERY CAPACITIES TEMPERATURE RISE - DEGREES °F (°C) Input Rating Water 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F MODEL BTU/Hr. (kW) Flow (22.2°) (27.7°) (33.3°) (38.8°) (44.4°) (50°) (55.5°) (61.1°) (66.7°) (72.2°) GW - 1000 990,000 (290.1...