Amana RSKP0006- User Manual

Amana RSKP0006

Amana RSKP0006– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Lift Off; Figure 2; New Control Board Installation Procedures; Figure 3; Figure 4
  • Page 4 – Figure 8; Condensate Pump Units Only
  • Page 5 – Power Vent/Power Door Units Only; Take caution not to bend or fold the
  • Page 6 – Figure 9
  • Page 7 – ON; YEL
  • Page 8 – WIRING DIAGRAMS
  • Page 11 – THIS PAGE LEFT INTENTIONALLY BLANK
  • Page 12 – Quality Makes the Difference!; There’s No Better Quality.; Visit our website at; is a trademark of Maytag Corporation and is used under
Loading the manual

Description

Control board installation procedures are described in detail
in these instructions. Read and follow these instructions
carefully before replacing the control board. Failure to do so
may result in control board damage.

Important Note:

Damage to the control board can occur from failure to
disconnect power supply or failure to set the master switch
(located on the control board) to OFF before removing the
low voltage terminal strip cover from an installed control
board. Damage to this board by not following these instruc-
tions is considered misuse and not covered under either the
standard unit warranty or any extended service contract.

Important Note:

All warranty replaced boards must be returned to the parts
source from which they were purchased to insure proper
warranty credit.

PTAC CONTROL BOARD KIT

RSKP0006

I

NSTALLATION

I

NSTRUCTIONS

IO-660A
November 2006

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation to know the product better than the customer. This

includes all safety precautions and related items.

Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention
to all safety warnings. Often during installation or repair it is possible to place yourself in a position which is

more hazardous than when the unit is in operation.

Remember, it is

your

responsibility to install the product safely and to know it well enough to be able to

instruct a customer in its safe use.

Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific

good safety practices...follow them.

The precautions listed in this Installation Manual are intended as supplemental to existing practices.

However, if there is a direct conflict between existing practices and the content of this manual, the

precautions listed here take precedence.

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

Figure 1

Electrostatic Discharge (ESD) Precautions

Before removing the new control board from the static wrap,
it is very important to discharge any static electricity. This
can be accomplished in two methods. Servicer can wear a
ground strap or by touching the metal chassis before replac-
ing the board.

Existing Control Board Removal Procedures

1. Disconnect power to the unit by unplugging the power

cord at the wall outlet or subbase, or disconnect power at
the fuse box or circuit breaker.

2. If the cabinet front is screwed to the chassis, remove the

1/4” screw (or screws) located behind the inlet grille. Pull
the inlet grille forward from the top of the grille to access
screw(s).

FRONT MOUNTING

HOLE

Printed in USA

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Lift Off; Figure 2; New Control Board Installation Procedures; Figure 3; Figure 4

2 3. Remove cabinet front from chassis by tilting the bottom of the front forward, lifting slightly up and forward. 4. If a remote thermostat or any low voltage accessory is being used, remove the low voltage pin connector from thelow voltage terminal strip. If a previous version board isbeing repla...

Page 4 - Figure 8; Condensate Pump Units Only

4 C. If the existing Indoor Coil Thermistor (with the RED wires) was connected to the board by a plug-onconnector, reconnect it to the new board on the ICT (red) terminals. If the previous board used indoor coilbi-metals, remove and discard the bi-metal devices.The access door will need to be remove...

Page 5 - Power Vent/Power Door Units Only; Take caution not to bend or fold the

5 19. Power Vent/Power Door Units Only (See Wiring Diagram Page 9) Reconnect the wires across the top terminals of thecontrol board. Connect as follows: Red 33 to Line 1 Brown 34 to heater 1 Brown 34 to Heater 2 Power cord (or black 18) to Line 2 Violet 12 to Compressor Blue 4 to Fan high Blue 15 an...

Other Amana Models