Amana RHF- User Manual

Amana RHF

Amana RHF– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – Safety Instructions; Safety Guidelines; Install the system in accordance with all local codes. If no local; WARNING; CAUTION; WARNING; To avoid personal injury, shock, or death, ensure the electrical
  • Page 3 – Refrigerant Piping; REFRIGERANT VAPOR AND LIQUID LINE SIZING; General; SHIPPING AND HANDLING; M IN IM U M C L E A R A N C E S; Figure 1
  • Page 4 – Safe Refrigerant Handling; REFRIGERANT VAPOR AND LIQUID LINE ROUTING; SWEAT CONNECTIONS AT THE UNIT
  • Page 5 – ID Coil and Line Sets Evacuation; ID COIL AND LINE SETS EVACUATION; Step 1. Confirm Proper Pump And Gauge Operation; LEAK TESTING
  • Page 7 – Electrical Connections; the final authority on wire sizing.
  • Page 8 – System Startup; PRELIMINARY CHARGE ADJUSTMENT; plus; IMPORTANT; FINAL CHARGE ADJUSTMENT; matching system; ID COIL WITH EXPANSION VALVE:; EXAMPLE
  • Page 9 – In
  • Page 10 – Tubing Size; Troubleshooting; Figure 5; SERVICING; To avoid electrical shock or death,
  • Page 13 – LOW
  • Page 14 – System Checklist
Loading the manual

Amana

1810 Wilson Parkway • Fayetteville, TN 37334

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation to

know the product better than the customer. This

includes all safety precautions and related items.
Prior to actual installation, thoroughly familiarize

yourself with this Instruction Manual. Pay special

attention to all safety warnings. Often during

installation or repair it is possible to place yourself

in a position which is more hazardous than when

the unit is in operation.

Remember, it is your responsibility to install the

product safely and to know it well enough to be able

to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of

thinking before acting. Most dealers have a list of

specific good safety practices...follow them.
The precautions listed in this Installation Manual

are intended as supplemental to existing practices.

However, if there is a direct conflict between existing

practices and the content of this manual, the

precautions listed here take precedence.

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

RHE**A2D & RHF**A2A

Remote Heat Pump

May 2001

Rev. 1

10652409

Table of Contents

Safety Instructions ............................................................. 2

General ................................................................................ 3

SHIPPING AND HANDLING ............................................................. 3

LOCATION AND CLEARANCES ...................................................... 3

ROOFTOP INSTALLATIONS ............................................................ 3

APPLICATION NOTE ........................................................................ 3

Refrigerant Piping ..................................................... 3

REFRIGERANT VAPOR AND LIQUID LINE SIZING ...................... 3

REFRIGERANT VAPOR AND LIQUID LINE ROUTING .................. 4

FILTER DRIER INSTALLATION ........................................................ 4

SWEAT CONNECTIONS AT THE UNIT ........................................... 4

Safe Refrigerant Handling .................................................. 4

LEAK TESTING ................................................................................ 5

ID COIL AND LINE SETS EVACUATION ......................................... 5

Step 1. Confirm Proper Pump And Gauge Operation ............. 5

Step 2. Evacuate Lines And Indoor Coil. ................................. 6

Electrical Connections ....................................................... 7

System Startup ................................................................... 8

PRELIMINARY CHARGE ADJUSTMENT ........................................ 8

FINAL CHARGE ADJUSTMENT ...................................................... 8

ID COIL WITH EXPANSION VALVE: ............................................... 8

ID COIL WITH ORIFICE (RHE MODELS ONLY) ............................. 8

Troubleshooting ............................................................... 10

Defrost System ................................................................. 10

SERVICING ..................................................................................... 10

Installation Instructions

Affix this manual, Specification Sheet and Users

Information Manual adjacent to the unit.

R

C

R

& RP IR UW4 XD OLW\7 UX VW

Heating

®

&

Air Conditioning

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Safety Instructions; Safety Guidelines; Install the system in accordance with all local codes. If no local; WARNING; CAUTION; WARNING; To avoid personal injury, shock, or death, ensure the electrical

2 Safety Instructions Safety Guidelines 1. Allow only qualified, experienced technicians to install or service this unit. 2. Install the system in accordance with all local codes. If no local codes exist, follow National Codes (NEC in the U.S., CEC in Canada). 3. Open the electrical disconnect switc...

Page 3 - Refrigerant Piping; REFRIGERANT VAPOR AND LIQUID LINE SIZING; General; SHIPPING AND HANDLING; M IN IM U M C L E A R A N C E S; Figure 1

3 3 DO NOT locate the unit: – Directly under a vent termination for a gas appliance.– Within 3 feet of a clothes drier vent.– Where the refreezing of defrost water would create a hazard. – Where water may rise into the unit.– Where the noise would prove to be a nuisance to the customer (i.e. windows...

Page 4 - Safe Refrigerant Handling; REFRIGERANT VAPOR AND LIQUID LINE ROUTING; SWEAT CONNECTIONS AT THE UNIT

4 Safe Refrigerant Handling WARNING To avoid possible explosion, death, or i n j u r y ; p r a c t i c e s a f e h a n d l i n g o f refrigerants. While these items will not cover every conceivable situa- tion, they should serve as a useful guide. WARNING Refrigerants are heavier than air. They can ...

Other Amana Models