Amana NGD7300W - Manual

Amana NGD7300W

Amana NGD7300W – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

Gas Dryer

PRODUCT MODEL NUMBERS
NGD7300W

Gas supply

:

This dryer is equipped for use with Natural

gas. Dryer can be converted to L.P. gas. When rigid

pipe is used it should be 1/2" IPS. When acceptable

to the gas supplier and local codes, 3/8" approved

tubing may be used for lengths under 20 ft (6.1 m).

For lengths over 20 ft (6.1 m), larger tubing should be

used. Pipe-joint compounds resistant to the action of

L.P. gas must be used. An individual manual shutoff

valve must be installed within 6 ft (1.8 m) of the dryer

in accordance with the National Fuel Gas Code ANSI

Z223.1.

Electrical

:

A 120-volt, 60 Hz, AC-only, 15 or 20 amp

fused electrical supply is required. A time-delay fuse or

circuit breaker and a separate circuit are recommended.

Water

(Steam models only)

:

The dryer must be

connected to the cold water faucet using new inlet

hoses. Do not use old hoses. Do not overtighten.

Damage to the coupling can result.

4"

(102 mm)

2½"

(64 mm)

4"

(102 mm)

4"

(102 mm)

B

A

A. Louvered hood
B. Box hood
C. Angled hood (acceptable)

C

Because Whirlpool Corporation policy includes a continuous commitment to improve

Dimensions are for planning purposes only. For complete details, see Installation

our products, we reserve the right to change materials and specifications without notice.

Instructions packed with product. Specifications subject to change without notice.

Ref. W10240584C

11/2010

OVERALL DIMENSIONS

Dryer dimensions

Select the route that will provide the straightest and most

direct path outdoors. Plan the installation to use the fewest

number of elbows and turns. Use the fewest 90° turns

possible.
Do not use vent runs longer than specified in vent length

chart.
Determine the number of elbows you will need.

For closet installation, with a door, the minimum ventilation openings in the top

and bottom of the door are required. Louvered doors with equivalent air ventilation

openings are acceptable.

Exhaust venting

:

Exhaust your dryer to the outside.

4" (102 mm) diameter vent is required. Rigid or flexible

metal exhaust vent must be used. Do not use plastic

or metal foil vet. Exhaust hood must be at least

12" (305 mm) from the ground or any object that

may be in the path of the exhaust.

Hood styles: A & B are recommended.

The vent system chart provides venting requirments

that will help to achieve the best drying performance.

Vent system chart:

NOTE:

Side and bottom exhaust installations have

a 90° turn inside the dryer. To determine maximum

exhaust length, add one 90° turn to the chart.

Cabinet and closet dimensions

6

1

/

4

"

(159 mm)

28

1

/

8

"

(715 mm)

3

1

/

2

"

(89 mm)

14"

(358 mm)

Electric

Front view

Side view

Back view

Stacked washer and

dryer installation

Closet (dryer only) installation

Cabinet (dryer only) installation

Custom under counter (dryer only)

installation

Number of

90 turns

or elbows

Type of

vent

Box or

Louvered

hoods

Angled

hoods

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

1

54 ft (16.5 m)

48 ft (14.6 m)

2

44 ft (13.4 m)

38 ft (11.6 m)

3

35 ft (10.7 m)

29 ft (8.8 m)

4

27 ft (8.2 m)

21 ft (6.4 m)

Rigid metal

Rigid metal

Rigid metal

Rigid metal

o

27"

(686 mm)

1"

(25 mm)

35

3

/

8

"

(899 mm)

3

1

/

2

"

(89 mm)

29"

(736 mm)

Left or

right side

exhaust

6

7

/

8

"

(174 mm)

1

5

/

8

"

(41 mm)

47

1

/

8

"

(1197 mm)

48

1

/

8

"

(1238 mm)

Door Open view

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

1"

(25 mm)

1"

(25 mm)

4"

(102 mm)

3"

(76 mm)

34" recommended

(864 mm)

18" min.

(457 mm)

3"

(76 mm)

1"

(25 mm)

1"

(25 mm)

4"

(102 mm)

7"

(178 mm)

18"

(460 mm)

1"

(25 mm)

1"

(25 mm)

39" min.

(990 mm)

1"

(25 mm)

1"

(25 mm)

5

1

/

2

"

(140 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

6"

(152 mm)

76"

(1930 mm)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.