Amana GUD-X- User Manual

Amana GUD-X

Amana GUD-X– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – For most jobs, about 400 CFM per ton when cooling is desirable.
  • Page 3 – Flame Sensor; Side Return Filters; * As Shipped With Furnace; Filter Retainer; WARNING; CLEARANCES TO COMBUSTIBLE SURFACES; C = If placed on combustible floor, floor MUST be wood only.; High Altitude Installations
  • Page 4 – CONTROL
Loading the manual

Amana

Fayetteville, TN 37334

A higher standard of comfort

Heating

¡

Air Conditioning

®

11134620

GUD-X

High Efficiency

Gas Fired

Warm Air Furnace

Due to continuous engineering de-
sign and development, the above
information is subject to change with-
out notice.

Affix this Specification Sheet, Installation Instructions and

User Information manual adjacent to the unit.

Specification Sheet

1

Minimum Circuit Ampacity = (Circulating Blower Amps x 1.25) + I.D. Blower Amps

2

Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size.

3

As shipped for installations below 4,000 feet.

Dimensions

WARNING

To avoid death, personal injury or
property damage due to fire, do not
exceed maximum recommended
fuse or circuit breaker size.

All dimensions are in inches.

Temp.

Blower

Pressure

Model Number

Input

(BTUH)

Output

(BTUH)

AFUE

Rise

Range, °F

Number

of

Burners

Minimum

Circuit

Ampacity

1

Maximum

Overcurrent

Protection

2

D" x W"

HP

Speeds

AC Tons @

.5 ESP

Switch Setting

(Inches W.C.)

3

Shipping

Weight

(lbs)

GUD045X30B

45,000

43,000

95.6

25-55

2

11.3

15

10X8

1/3

3

2.0-3.0

-1.38

158

GUD070X30B

70,000

65,700

93.8

35-65

3

10.3

15

10X8

1/3

4

2.0-3.0

-1.38

194

GUD070X40B

70,000

65,700

93.8

35-65

3

14.1

15

10X10

3/4

4

3.0-4.0

-1.38

194

GUD090X35B

90,000

84,300

93.7

45-75

4

10.1

15

10X8

1/2

4

2.0-3.5

-1.57

216

GUD090X50B

90,000

85,100

94.6

35-65

4

15.1

20

10X10

3/4

4

3.5-5.0

-1.57

216

GUD115X50B

115,000

107,600

93.6

35-65

5

15.1

20

10X10

3/4

4

3.5-5.0

-1.38

231

Size

A

B

C

D

E

45

16-1/2

15

7

10-1/2

2-5/8

70

20-1/2

19

11

14-1/2

2-5/8

90

24-1/2

23

10-1/2

18-1/2

4-5/8

115

24-1/2

23

12-1/2

18-1/2

2-5/8

Top View

Gas Supply Hole

Electrical Hole

Line Voltage

1-3/4

2

Combustion

Air Inlet

Flue Outlet

4-1/4

4-3/8

2-1/2

C

E

1-1/8

Front View

Left Side View

28-1/8

28

20-1/8

23

28-3/4

38-3/4

40

48

23

Bottom KO

14

A

B

16-1/2

38-1/4

3/4

2-3/8

3/4

1-5/8

1-5/8

3/4

Bottom KO

D

Side KO

Electrical

Hole-Low

Voltage

Gas

Supply

Hole

Electrical

Hole-Line

Voltage

Supply

1-5/8

5-7/8

6-5/8

Condensate Drain

(Left or Right Side)

38-3/4

Right Side View

4-3/4

6-5/8

Supply

Gas

Supply

Hole

Electrical

Hole-Low

Voltage

January 1998

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - For most jobs, about 400 CFM per ton when cooling is desirable.

2 NOTES: • CFM information in the above table is with high velocity, permanent filter(s) as shipped with the furnace. If the furnace is shipped with twoside return filters, this table assumes both filters are used. • All furnaces ship as high speed for cooling. Installer must adjust blower speed as ...

Page 3 - Flame Sensor; Side Return Filters; * As Shipped With Furnace; Filter Retainer; WARNING; CLEARANCES TO COMBUSTIBLE SURFACES; C = If placed on combustible floor, floor MUST be wood only.; High Altitude Installations

3 5. Drain connections must conform to local codes. 6. Installer must supply the following gas line fittings according to which entrance is used: Top Two 90° ElbowsOne Close Nipple Left One 90° Elbow Right One 90° ElbowOne 45° ElbowOne Close Nipple Flame Sensor Flame sensor output is 1 to 4 microamp...

Page 4 - CONTROL

4 To prevent death, personal injury or property damage due to electrical shock, disconnect electrical power to this furnacebefore servicing or performing maintenance. WARNING COOLING YL YELLOWOR ORANGEVT VIOLETGN GREENBK BLACKBR BROWNWH WHITE BU BLUEGY GRAYRD RED COLOR CODE LOW VOLTAGE LOW VOLTAGE F...

Other Amana Models