Amana GUD-X- User Manual
Amana GUD-X– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – For most jobs, about 400 CFM per ton when cooling is desirable.
- Page 3 – Flame Sensor; Side Return Filters; * As Shipped With Furnace; Filter Retainer; WARNING; CLEARANCES TO COMBUSTIBLE SURFACES; C = If placed on combustible floor, floor MUST be wood only.; High Altitude Installations
- Page 4 – CONTROL
Amana
Fayetteville, TN 37334
A higher standard of comfort
Heating
¡
Air Conditioning
®
11134620
GUD-X
High Efficiency
Gas Fired
Warm Air Furnace
Due to continuous engineering de-
sign and development, the above
information is subject to change with-
out notice.
Affix this Specification Sheet, Installation Instructions and
User Information manual adjacent to the unit.
Specification Sheet
1
Minimum Circuit Ampacity = (Circulating Blower Amps x 1.25) + I.D. Blower Amps
2
Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size.
3
As shipped for installations below 4,000 feet.
Dimensions
WARNING
To avoid death, personal injury or
property damage due to fire, do not
exceed maximum recommended
fuse or circuit breaker size.
All dimensions are in inches.
Temp.
Blower
Pressure
Model Number
Input
(BTUH)
Output
(BTUH)
AFUE
Rise
Range, °F
Number
of
Burners
Minimum
Circuit
Ampacity
1
Maximum
Overcurrent
Protection
2
D" x W"
HP
Speeds
AC Tons @
.5 ESP
Switch Setting
(Inches W.C.)
3
Shipping
Weight
(lbs)
GUD045X30B
45,000
43,000
95.6
25-55
2
11.3
15
10X8
1/3
3
2.0-3.0
-1.38
158
GUD070X30B
70,000
65,700
93.8
35-65
3
10.3
15
10X8
1/3
4
2.0-3.0
-1.38
194
GUD070X40B
70,000
65,700
93.8
35-65
3
14.1
15
10X10
3/4
4
3.0-4.0
-1.38
194
GUD090X35B
90,000
84,300
93.7
45-75
4
10.1
15
10X8
1/2
4
2.0-3.5
-1.57
216
GUD090X50B
90,000
85,100
94.6
35-65
4
15.1
20
10X10
3/4
4
3.5-5.0
-1.57
216
GUD115X50B
115,000
107,600
93.6
35-65
5
15.1
20
10X10
3/4
4
3.5-5.0
-1.38
231
Size
A
B
C
D
E
45
16-1/2
15
7
10-1/2
2-5/8
70
20-1/2
19
11
14-1/2
2-5/8
90
24-1/2
23
10-1/2
18-1/2
4-5/8
115
24-1/2
23
12-1/2
18-1/2
2-5/8
Top View
Gas Supply Hole
Electrical Hole
Line Voltage
1-3/4
2
Combustion
Air Inlet
Flue Outlet
4-1/4
4-3/8
2-1/2
C
E
1-1/8
Front View
Left Side View
28-1/8
28
20-1/8
23
28-3/4
38-3/4
40
48
23
Bottom KO
14
A
B
16-1/2
38-1/4
3/4
2-3/8
3/4
1-5/8
1-5/8
3/4
Bottom KO
D
Side KO
Electrical
Hole-Low
Voltage
Gas
Supply
Hole
Electrical
Hole-Line
Voltage
Supply
1-5/8
5-7/8
6-5/8
Condensate Drain
(Left or Right Side)
38-3/4
Right Side View
4-3/4
6-5/8
Supply
Gas
Supply
Hole
Electrical
Hole-Low
Voltage
January 1998
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 NOTES: • CFM information in the above table is with high velocity, permanent filter(s) as shipped with the furnace. If the furnace is shipped with twoside return filters, this table assumes both filters are used. • All furnaces ship as high speed for cooling. Installer must adjust blower speed as ...
3 5. Drain connections must conform to local codes. 6. Installer must supply the following gas line fittings according to which entrance is used: Top Two 90° ElbowsOne Close Nipple Left One 90° Elbow Right One 90° ElbowOne 45° ElbowOne Close Nipple Flame Sensor Flame sensor output is 1 to 4 microamp...
4 To prevent death, personal injury or property damage due to electrical shock, disconnect electrical power to this furnacebefore servicing or performing maintenance. WARNING COOLING YL YELLOWOR ORANGEVT VIOLETGN GREENBK BLACKBR BROWNWH WHITE BU BLUEGY GRAYRD RED COLOR CODE LOW VOLTAGE LOW VOLTAGE F...