Amana GUCA070AX40- User Manual

Amana GUCA070AX40

Amana GUCA070AX40– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4
Loading the manual

May 1998 (3)

11134619

GUCA

High Efficiency

Gas Fired Warm Air Furnace

D u e t o c o n t i n u o u s e n g i n e e r i n g
d e s i g n a n d d e v e l o p m e n t , t h e
information in this spec sheet is
subject to change without notice.

All dimensions are in inches.

Affix this Specification Sheet, Installation Instructions

and User Information manual adjacent to the unit.

Specification Sheet

Dimensions

(Inches)

WARNING

To avoid death, personal injury or
property damage due to fire, do not
exceed maximum recommended
fuse or circuit breaker size.

A higher standard of comfort

Heating

¡

Air Conditioning

®

Cabinet

Size

Units

A

B

C

D

045__30

070__30
070__40

090__40
090__50

115__50

12-5/8

14-5/8

18-5/8

12-3/8

16-3/8

20-3/8

15

19

23

16-1/2

20-1/2

24-1/2

Small

Medium

Large

AIR

DISCHARGE

AIR

DISCHARGE

ALTERNATE

GAS SUPPLY

HOLE

LOW VOLTAGE

ELECTRICAL HOLE

HIGH VOLTAGE

ELECTRICAL HOLE

SIDE KNOCK OUT

LEFT SIDE

VIEW

SIDE KNOCK OUT

HIGH VOLTAGE
ELECTRICAL HOLE

LOW VOLTAGE
ELECTRICAL HOLE

RIGHT SIDE

DRAIN LINE

HOLES

ALTERNATE
VENT/FLUE
LOCATION

STANDARD GAS
SUPPLY HOLE

DRAIN

TRAP

28 3/4

3/4

20 5/16

2 1/2

AIR INTAKE PIPE

2" PVC

7 3/8

LEFT SIDE

DRAIN LINE

HOLES

1 3/4

DRAIN

TRAP

C

L

1 1/2

1 5/8

30 1/4

9 3/8

11 3/4

19 3/16

23

BOTTOM KNOCK OUT

25 9/16

4 1/8

2 11/16

VENT/FLUE PIPE

2" PVC

RIGHT SIDE

VIEW

2 5/8

30 1/4

32 13/16

27 1/8

19 3/16

2 5/8

11 3/4

ALTERNATE
AIR INTAKE LOCATION

7 7/8

C

L

6 1/8

1 3/4

CONDENSATE

DRAIN TRAP

w/ 3/4" PVC

DISCHARGE

(RIGHT OR

LEFT SIDE)

3/4

40

3/4

2 1/16

2

BOTTOM KNOCK OUT

C

B

D

FRONT

VIEW

16 3/8

A

(DISCHARGE)

14

Model

Input

Output

Temp.

Rise

Number

of

Minimum

Circuit

Maximum

Overcurrent

Circulator Blower

Tons AC

at

Pressure

Switch Settings

(Inches W.C.)

Shipping

W eight

Number

(Btu/hr)

(Btu/hr)

Range

(F)

Burners

Ampacity

1

(Amps)

Protection

2

(Amps)

Size

(D" x W ")

HP

Number

of Speeds

0.5" ESP

ID

Blwr

Front

Cover

(lbs)

GUCA045AX30

46,000

42,200

92.0

35 - 65

2

9.0

15.0

11 X 6

1/3

4

1.5 - 3.0

-0.37

-0.37

131

GUCA070AX30

69,000

63,800

92.0

35 - 65

3

8.9

15.0

11 X 7

1/2

4

2.0 - 3.5

-0.37

-0.37

144

GUCA070AX40

69,000

63,300

92.0

35 - 65

3

8.9

15.0

11 X 9

1/2

4

2.5 - 4.0

-0.37

-0.37

152

GUCA090AX40

92,000

86,000

92.0

35 - 65

4

8.9

15.0

11 X 9

1/2

4

2.5 - 4.0

-0.37

-0.37

166

GUCA090AX50

92,000

85,100

92.0

35 - 65

4

13.8

15.0

11 X 9

3/4

4

3.0 - 5.0

-0.37

-0.37

175

GUCA115AX50

115,000 105,900

92.0

35 - 65

5

14.9

15.0

11 X 10

3/4

4

3.0 - 5.0

-0.37

-0.37

187

1

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower Amps.

2

Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size.

3

As shipped for installations below 7,000 feet.

AFUE

3

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Amana Models