Amana GUCA070AX40- User Manual
Amana GUCA070AX40– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
May 1998 (3)
11134619
GUCA
High Efficiency
Gas Fired Warm Air Furnace
D u e t o c o n t i n u o u s e n g i n e e r i n g
d e s i g n a n d d e v e l o p m e n t , t h e
information in this spec sheet is
subject to change without notice.
All dimensions are in inches.
Affix this Specification Sheet, Installation Instructions
and User Information manual adjacent to the unit.
Specification Sheet
Dimensions
(Inches)
WARNING
To avoid death, personal injury or
property damage due to fire, do not
exceed maximum recommended
fuse or circuit breaker size.
A higher standard of comfort
Heating
¡
Air Conditioning
®
Cabinet
Size
Units
A
B
C
D
045__30
070__30
070__40
090__40
090__50
115__50
12-5/8
14-5/8
18-5/8
12-3/8
16-3/8
20-3/8
15
19
23
16-1/2
20-1/2
24-1/2
Small
Medium
Large
AIR
DISCHARGE
AIR
DISCHARGE
ALTERNATE
GAS SUPPLY
HOLE
LOW VOLTAGE
ELECTRICAL HOLE
HIGH VOLTAGE
ELECTRICAL HOLE
SIDE KNOCK OUT
LEFT SIDE
VIEW
SIDE KNOCK OUT
HIGH VOLTAGE
ELECTRICAL HOLE
LOW VOLTAGE
ELECTRICAL HOLE
RIGHT SIDE
DRAIN LINE
HOLES
ALTERNATE
VENT/FLUE
LOCATION
STANDARD GAS
SUPPLY HOLE
DRAIN
TRAP
28 3/4
3/4
20 5/16
2 1/2
AIR INTAKE PIPE
2" PVC
7 3/8
LEFT SIDE
DRAIN LINE
HOLES
1 3/4
DRAIN
TRAP
C
L
1 1/2
1 5/8
30 1/4
9 3/8
11 3/4
19 3/16
23
BOTTOM KNOCK OUT
25 9/16
4 1/8
2 11/16
VENT/FLUE PIPE
2" PVC
RIGHT SIDE
VIEW
2 5/8
30 1/4
32 13/16
27 1/8
19 3/16
2 5/8
11 3/4
ALTERNATE
AIR INTAKE LOCATION
7 7/8
C
L
6 1/8
1 3/4
CONDENSATE
DRAIN TRAP
w/ 3/4" PVC
DISCHARGE
(RIGHT OR
LEFT SIDE)
3/4
40
3/4
2 1/16
2
BOTTOM KNOCK OUT
C
B
D
FRONT
VIEW
16 3/8
A
(DISCHARGE)
14
Model
Input
Output
Temp.
Rise
Number
of
Minimum
Circuit
Maximum
Overcurrent
Circulator Blower
Tons AC
at
Pressure
Switch Settings
(Inches W.C.)
Shipping
W eight
Number
(Btu/hr)
(Btu/hr)
Range
(F)
Burners
Ampacity
1
(Amps)
Protection
2
(Amps)
Size
(D" x W ")
HP
Number
of Speeds
0.5" ESP
ID
Blwr
Front
Cover
(lbs)
GUCA045AX30
46,000
42,200
92.0
35 - 65
2
9.0
15.0
11 X 6
1/3
4
1.5 - 3.0
-0.37
-0.37
131
GUCA070AX30
69,000
63,800
92.0
35 - 65
3
8.9
15.0
11 X 7
1/2
4
2.0 - 3.5
-0.37
-0.37
144
GUCA070AX40
69,000
63,300
92.0
35 - 65
3
8.9
15.0
11 X 9
1/2
4
2.5 - 4.0
-0.37
-0.37
152
GUCA090AX40
92,000
86,000
92.0
35 - 65
4
8.9
15.0
11 X 9
1/2
4
2.5 - 4.0
-0.37
-0.37
166
GUCA090AX50
92,000
85,100
92.0
35 - 65
4
13.8
15.0
11 X 9
3/4
4
3.0 - 5.0
-0.37
-0.37
175
GUCA115AX50
115,000 105,900
92.0
35 - 65
5
14.9
15.0
11 X 10
3/4
4
3.0 - 5.0
-0.37
-0.37
187
1
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower Amps.
2
Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size.
3
As shipped for installations below 7,000 feet.
AFUE
3
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.