  • Page 2 – This unit must not be used as a “construction
  • Page 3 – Counterflow Installation over a combustible floor.; ADDITIONAL LOCATION; CONSIDERATIONS; II. General Information; WARNING; ADDITIONAL SAFETY CONSIDERATIONS
  • Page 4 – III. Combustion and Ventilation Air; AIR REQUIREMENTS; National Fuel Gas Code; (c) In addition to air needed for combustion, process air shall be
  • Page 6 – Figure 5; When directly communicating with the outdoors, the single; Special Conditions Created by Mechanical Exhausting or; Operation of exhaust fans, ventilation systems, clothes dryers, or; MINIMUM VENT DIAMETER
  • Page 7 – Vent; Section VI, Electrical Wiring
  • Page 8 – V. Gas Supply and Piping; GENERAL; CAUTION; Adjusting the minimum supply pressure below the; High Altitude Derate; derate the furnace by adjusting the manifold pres-; Propane Gas Conversion
  • Page 9 – GAS PIPING CONNECTIONS; General; Figure 8; Upflow Installations; Figure 9
  • Page 10 – Gas Inlet Through Furnace Bottom Side; Straight pipe to reach the exterior of the furnace. See; Gas Inlet Through Furnace Left Side; Counterflow Installations; , the installer must supply a straight pipe to reach; Gas Inlet Through Left Side
  • Page 11 – Gas Inlet Through Right Side (Counterflow); Gas Piping Checks; Propane Gas Tanks and Piping
  • Page 12 – Refer to Figure 16 for typical propane gas installations.; Typical Propane Gas Installations; PROPANE GAS PIPING CHARTS; Vl. Electrical Wiring; THERMOSTAT REQUIREMENTS; NOTE; Typical Field Wiring
  • Page 13 – ground wire; Heating Fan; Integrated Ignition Control
  • Page 14 – AIR CIRCULATION BLOWER TIMING; Switches; Accessory Load Specification; Control Module; Accessory Operation; Accessory Operation:; The furnace control module ener-; VlI. Circulating Air and Filters
  • Page 15 – UPRIGHT INSTALLATIONS; Possible Upright Upflow; Possible Upright Counterflow; HORIZONTAL INSTALLATIONS; VIII. Sequence of Operation; Refer to Timing Charts for sequencing.
  • Page 16 – balance; GENERAL OPERATION; Right To Left Installation
  • Page 17 – Rollout Switch Relocation; BURNER BOX; Auxiliary Limit Control
  • Page 20 – Indoor Fan
  • Page 21 – Diagnostic Signal Chart
  • Page 22 – Gas Pressure; With Power and Gas Off:; Gas Manifold Pressure Measurement and Adjustment
  • Page 23 – Gas Adjustments; Natural Gas; Gas Input Rate measurement (Natural Gas Only)
  • Page 24 – ANNUAL INSPECTION; High Limit Control; HIGH LIMIT CONTROL CHECK; FURNACE SHUTDOWN
  • Page 25 – AIR FILTER - UPFLOW FURNACES; Filter Removal; AIR FILTER - COUNTERFLOW FURNACES
  • Page 26 – FILTER; Filter Rack Mounted On; AIR CIRCULATING BLOWER MOTOR; Burner Flame
Loading the manual

Amana

1810 Wison Parkway • Fayetteville, TN 37334

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation to
know the product better than the customer. This
includes all safety precautions and related items.
Prior to actual installation, thoroughly familiarize
yourself with this Instruction Manual. Pay special
attention to all safety warnings. Often during
installation or repair it is possible to place yourself
in a position which is more hazardous than when
the unit is in operation.

Remember, it is your responsibility to install the
product safely and to know it well enough to be able
to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of
thinking before acting. Most dealers have a list of
specific good safety practices...follow them.
The precautions listed in this Installation Manual
are intended as supplemental to existing practices.
However, if there is a direct conflict between existing
practices and the content of this manual, the
precautions listed here take precedence.

October 2001
Rev. 5

10759825

Amana Forced Air Central Furnace Design Complies With Requirements
Embodied in The American National Standard / National Standard of Canada
Shown Below.
ANSI Z21.47•CSA-2.3 Central Furnaces

Table of Contents

To The Owner .............................................................. 2

To The Installer ........................................................... 2

I. Safety and Unit Location ..................................... 2

II. General Information ............................................. 3

III. Combustion and Ventilation Air Requirements . 4

IV. Category I Venting (Vertical Venting) .................. 6

V. Gas Supply and Piping ........................................ 8

Vl. Electrical Wiring ................................................. 12

VlI. Circulating Air and Filters ................................. 14

VIII. Sequence of Operation ..................................... 15

IX. Start-Up, Adjustments, and Checks .................. 16

X. Maintenance ....................................................... 24

GUIS/GCIS

Two-Stage Gas-Fired

Warm Air Furnace

Installation Instructions

Affix this manual, Specification Sheet and Users

Information Manual adjacent to the furnace.

DESIGN

C E R T I FI E D

C E R T I F I E D

C o m f o rt. Q u a l ity . T ru s t.

Heating

®

&

Air Conditioning

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - This unit must not be used as a “construction

2 WARNING If the information in these instructions isnot followed exactly, a fire or explosionmay result causing property damage,personal injury or loss of life.– Do not store or use gasoline or other flammable vapors and liquids in thevicinity of this or any other appliance. – What to do if you sme...

Page 3 - Counterflow Installation over a combustible floor.; ADDITIONAL LOCATION; CONSIDERATIONS; II. General Information; WARNING; ADDITIONAL SAFETY CONSIDERATIONS

3 level. A tight seal should be made between the furnace base and floor by using a silicone rubber caulking compound or cement grout. • Counterflow Installation over a combustible floor. If installation over a combustible floor becomes neces- sary, use an accessory subbase as shown on the Specificat...

Page 4 - III. Combustion and Ventilation Air; AIR REQUIREMENTS; National Fuel Gas Code; (c) In addition to air needed for combustion, process air shall be

4 TRANSPORTATION DAMAGE Check the furnace for any shipping damage. If damage isfound, contact the company where the furnace was pur-chased.While checking for transportation damage, remove allpackaging material and dispose or recycle according tolocal codes. THERMOSTAT REQUIREMENTS The two stage furn...