Amana CKF48- User Manual

Amana CKF48

Amana CKF48– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
Page: / 60

Table of Contents:

  • Page 2 – IMPORTANT INFORMATION; REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATE; IMPORTANT NOTICES FOR CONSUMERS AND SERVICERS; RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS; TABLE OF CONTENTS; WARNING
  • Page 3 – SAFE REFRIGERANT HANDLING; See Service Section S-17 for proper servicing.; Never purge refrigerant into an enclosed room or
  • Page 4 – PRODUCT IDENTIFICATION; PKF; Electrical Supply; Amana
  • Page 5 – KF
  • Page 7 – THIS NOMENCLATURE IS TO BE USED AFTER JULY 2006; All Airhandlers use; DIRECT DRIVE; Power supply is
  • Page 8 – MB; Design Series; A: No Circuit Breaker
  • Page 9 – ACCESSORIES
  • Page 11 – For Applications requiring; For Applications not requiring; EXPANSION VALVE KITS
  • Page 12 – FREEZE THERMOSTAT
  • Page 13 – ELECTRIC HEAT KIT APPLICATIONS; HKR SERIES ELECTRIC HEAT KITS
  • Page 14 – PRODUCT DESIGN; CONDENSING UNIT; Suction and Liquid Line Connections; Compressor. There are a number of design character-; COILS AND BLOWER COILS
  • Page 15 – SYSTEM OPERATION; COOLING; HEATING; COOLING CYCLE
  • Page 18 – COOLING CYCLE - CONDENSING UNIT; In the cooling mode, the orifice is pushed into its
  • Page 19 – DESCRIPTION; , it recognizes this as a
  • Page 20 – TROUBLESHOOTING CHART; COOLING/HP ANALYSIS CHART
  • Page 21 – MBE & AEPF with Single Speed
  • Page 22 – SERVICING; REMOTE CONDENSING UNITS; ANTICIPATOR; THERMOSTAT WIRE SIZING CHART; S-3A THERMOSTAT AND WIRING; Line Voltage now present.; Indoor Blower Motor; Line Voltage now present.
  • Page 23 – Resistance Heaters; S-3B COOLING ANTICIPATOR; Troubleshooting Encoded Two Stage Cooling Thermostats Options
  • Page 24 – S-4 CHECKING TRANSFORMER; Discon nect ALL p ower before servicing.; S-5 CHECKING CYCLE PROTECTOR; S-6 CHECKING TIME DELAY RELAY; W A RN ING; Discon nect ALL power before servicing.; OHMMETER; TESTING COIL CIRCUIT
  • Page 25 – Remove the leads from the holding coil.; S-8 CHECKING CONTACTOR CONTACTS; DISCONNECT ELECTRICAL POWER SUPPLY.; Disconnect Electrical Power Supply:; Disconnect the wire leads from the terminal (T) side of the; If a no voltage reading is obtained - replace the contactor.; TESTING COMPRESSOR CONTACTOR; S-9 CHECKING FAN RELAY CONTACTS; Disconnect wires leads from terminals 2 and 4 of Fan
  • Page 26 – S-10 COPELAND COMFORT ALERTTM; See Diagnostic Table on
  • Page 27 – DIAGNOSTICS TABLE
  • Page 28 – S-13 CHECKING LOW PRESSURE CONTROL; SCROLL COMPRESSOR MODELS; S-11 CHECKING LOSS OF CHARGE PROTECTOR
  • Page 29 – HARD START KIT WIRING; S-15A RESISTANCE CHECK; Discharge capacitor and remove wire leads.; TESTING CAPACITOR RESISTANCE; Set an ohmmeter on its highest ohm scale and connect; S-15B CAPACITANCE CHECK; TESTING CAPACITANCE; Voltage; S-16A CHECKING FAN AND BLOWER MOTOR
  • Page 30 – S-16B CHECKING FAN AND BLOWER MOTOR; Electronically Commutated Motor; 6-PIN ECM HARNESS CONNECTOR
  • Page 31 – CHART CONTINUED ON NEXT PAGE
  • Page 32 – CHART CONTINUED FROM PREVIOUS PAGE
  • Page 33 – S-16C CHECKING ECM MOTOR WINDINGS; MBE MOTOR; MOTOR SPEED ADJUSTMENT; CFM DELIVERY; Tables 2; Model; Electric Heat Operation
  • Page 34 – Cooling/Heat Pump Operation; THERMOSTAT “FAN ONLY” MODE; Table 4; O N; HUMIDITY CONTROL; MOTORS; C L G N; High Voltage; MOTOR CONNECTIONS
  • Page 35 – S-17 CHECKING COMPRESSOR; S-17A RESISTANCE TEST; TESTING COMPRESSOR WINDINGS
  • Page 36 – COMPRESSOR GROUND TEST; COPELAND COMPRESSOR; Y E A R; Disconnect ALL power before servicing.; S-21 CHECKING REVERSING VALVE
  • Page 37 – TIME DELAY RELAY; Refer to the installation instruc-; WITH SINGLE STAGE; Cooling Operation; On most digital/electronic thermostats, “W2” will
  • Page 38 – Heating Operation; Defrost Operation
  • Page 39 – DENSERS
  • Page 40 – For the 3; heater elements to operate on a third
  • Page 41 – BTUH; TEMPERATURE RISE
  • Page 42 – S-61B CHECKING HEATER FUSE LINK; S-62 CHECKING HEATER ELEMENTS; S-100 REFRIGERATION REPAIR PRACTICE; BRAZING MATERIALS; Copper to Copper Joints
  • Page 43 – EVACUATION
  • Page 44 – SYSTEM SUPERHEAT; S-104 CHECKING COMPRESSOR EFFICIENCY
  • Page 45 – S-105B THERMOSTATIC EXPANSION VALVE; THERMOSTATIC EXPANSION VALVES
  • Page 46 – CHECKING SUPERHEAT; Gauge Pressure
  • Page 47 – S-109 CHECKING SUBCOOLING; Capillary Tubes/Orifice Assembly; S-112 CHECKING RESTRICTED LIQUID LINE
  • Page 48 – S-113 OVERCHARGE OF REFRIGERANT; NOTICE; Suction Line Drier Clean-Up Method; including
  • Page 49 – S-120 REFRIGERANT PIPING
  • Page 50 – TABLE 8. CAPACITY MULTIPLIERS AS A FUNCTION OF; Table 8; TABLE 9. LOSSES FROM SUCTION LINE ELBOWS; Table 9; In a completely horizontal installation with a long line set; Fig 6. Evaporator unit with inverted vapor loop; Preformed oil
  • Page 51 – S-122 REVERSING VALVE REPLACEMENT
  • Page 52 – Air Flow; TOTAL EXTERNAL STATIC; S-204 COIL STATIC PRESSURE DROP; A direct reading can be taken of the static pressure drop; STATIC PRESSURE DROP
  • Page 53 – ACCESSORIES WIRING DIAGRAMS; ALL FUEL SYSTEM CONTROL BOARD - AFE18-60A
  • Page 54 – 0kw and Below, One Stage Electric Heat; 5kw and Above, Two Stage Electric Heat
  • Page 56 – Typical Wiring Schematic ADPF, ARPF, ARUF with Electric Heat.
  • Page 57 – Typical Wiring Schematic MBR Blower with Electric Heat.
  • Page 58 – Typical Wiring Schematic AEPF with Electric Heat.
  • Page 59 – Blower Section; HKR Heat Kit; Typical Wiring Schematic MBE Blower with Electric Heat.
  • Page 60 – Typical Wiring Schematic ASPF with Electric Heat.
Loading the manual

RS6100004 Rev. 2

May 2007

Service
Instructions

Split System Air Conditioners and
Split System Heat Pumps
with R-22 Refrigerant
Blowers, Coils, & Accessories

This manual is to be used by qualified, professionally trained HVAC technicians only.
Goodman does not assume any responsibility for property damage or personal injury due
to improper service procedures or services performed by an unqualified person.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - IMPORTANT INFORMATION; REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATE; IMPORTANT NOTICES FOR CONSUMERS AND SERVICERS; RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS; TABLE OF CONTENTS; WARNING

IMPORTANT INFORMATION Pride and workmanship go into every product to provide our customers with quality products. It is possible, however,that during its lifetime a product may require service. Products should be serviced only by a qualified service technicianwho is familiar with the safety procedur...

Page 3 - SAFE REFRIGERANT HANDLING; See Service Section S-17 for proper servicing.; Never purge refrigerant into an enclosed room or

3 The successful development of hermetically sealed refrigera-tion compressors has completely sealed the compressor'smoving parts and electric motor inside a common housing,minimizing refrigerant leaks and the hazards sometimesassociated with moving belts, pulleys or couplings. Fundamental to the de...

Page 4 - PRODUCT IDENTIFICATION; PKF; Electrical Supply; Amana

PRODUCT IDENTIFICATION 4 C PKF 036 2 A Electrical Supply Unit Type E: Commercial Air ConditionerK: Air ConditionerP: Heat Pump Product Category C: Split System 1: 208-230V/60Hz/1ph 2: 220-240V/50Hz/1ph 3: 208/230V/60Hz/3ph 4: 308/415V/50Hz/3ph Revision Nominal Capacity 018: 1.5 tons024: 2 tons 030: ...

Other Amana Models