- Page 2 – Alpine Components
- Page 3 – high sensitivity; position. 0 is a dB indication of
- Page 4 – RUBBER FOCUSING PROBE
- Page 5 – To use the; WARBLE TONE GENERATOR; To charge the Warble Tone Generator:
- Page 6 – ULTRAPROBE APPLICATIONS; A. HOW TO LOCATE LEAKS; over the scanning module and proceed to scan the test area.
- Page 7 – C. OVERCOMING DIFFICULTIES; Competing Ultrasounds; SHIELDING TECHNIQUES; barrier between the test area and the competing sounds
- Page 11 – DETECTING BEARING WEAR; monitored frequencies.
- Page 13 – LOCATING FAULTY STEAM TRAPS; When testing steam traps ultrasonically:
- Page 14 – directly by phone or fax.
- Page 15 – LOCATING FAULTY VALVES
- Page 17 – S P E C I F I C AT I O N S; Construction
- Page 18 – WA R N I N G; lockout and maintenance procedures.; procedures when attempting repairs.; Do not; touch live electrical equipment with your instrument.
ULTRAPROBE
TM
100
I N S T R U C T I O N M A N U A L
VOLUME 1.3
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
NEED HELP??? HAVE QUESTIONS?? AT UE SYSTEMS, WE ARE DEDICATED TO SUPPORTING OUR ULTRAPROBE USERS. OUR STAFF HAS YEARS OF FIELD EXPERIENCE AND IS STANDING READY TO ASSIST YOU SHOULD YOU NEED US. WHEREVER YOU ARE, REMEMBER, WE ARE AS CLOSE AS YOUR PHONE, FAX OR COMPUTER. CALL: 914-592-1220 FAX: 914-34...
The ULTRAPROBE 100 provides easy, accurate leak detection and mechanical inspection through advanced ultrasonic technology. Before you begin testing, it is advisable to familiarize yourself with the basic components of your kit. 1. PISTOL HOUSING The main component of the Ultraprobe is its' pistol h...
2. SCANNING MODULE This module is utilized to receive air-borne ultrasound such as the ultrasounds emitted by pressure leaks and electrical discharges. To use, make sure it is plugged in to the front end of the metered pistol housing by aligning the plug with the receptical and inserting it firmly. ...