AT-PWR3202 Power Supply Installation Guide

Overview

AT-PWR3202 Power Supply is designed to be installed in an AT-RPS3204
Redundant Power Supply (RPS). The RPS can supply power to Allied Telesis
switches if the switch’s main power supply fails

.

Verifying Package Contents

Verify that the correct components are included in your package:

AT-PWR3202 Power Supply

One 21-pin D-combo connector cable

This installation guide

If any item is missing or damaged, contact your Allied Telesis sales
representative for assistance.

Warranty

The AT-PWR3202 Power Supply has a Lifetime Year Warranty (Five Years
Power Supply and Fan). For detailed warranty information, see the
www.alliedtelesis.com website.

Installing the Power Supply

To install an AT-PWR3202 Power Supply, perform the following procedure:
1. Remove the AT-PWR3202 unit from its shipping package and store the

package in a safe place. You must use the original package if you need to
return the power supply to Allied Telesis.

2. On the back of the AT-RPS3204 unit, locate the power switch that

corresponds to the slot where you are going to install the power supply and
verify that the On/Off button is in the Off (out) position. From left to right on
the back, the power supplies are identified as B2, B1, A2, A1. (An AT-
RPS3204 is shipped with one AT-PWR3202 in the slot marked A1.)

3. Using a Phillips head screwdriver, remove the cover from the slot in the front

of the AT-RPS3204 unit where you want to install the power supply.

Note

As an example, the following steps show an AT-PWR3202 unit installed in
slot A2 of the AT-RPS3204 Redundant Power Supply.

Keep the slot cover in a safe area in case you remove a power supply. The
slot cover helps maintain proper air flow through the RPS.

4. Slide the AT-PWR3202 Power Supply into the slot

5. Use a Phillips head screwdriver to tighten the captive screws.

6. On the back of the AT-RPS3204 unit, plug one end of the 21-pin D-combo

connector cable into the connector that corresponds to the slot in which you
installed the AT-RPS3202 Power Supply.

7.

Tighten the captive screws.

892

STA

TUS

POWER

FAULT

AT-PW

R3202

12VDC

,16.6A MA

X

STATUS

POWE

R

FAULT

STATUS

POW

ER

FAULT

893

AT-PW

R320

2

12VDC

,16.6A

MAX

STATUS

POWER

FAULT

STATUS

POWER

FAULT

894

STATU

S

POWER

FAUL

T

AT-PW

R320

2

12VD

C ,16.6A

MAX

AT-PW

R320

2

12VD

C

,16.6A

MAX

STATUS

POW

ER

FAULT

STATUS

POWER

FAULT

895

STATUS

POWER

FAUL

T

AT-PW

R3202

12VD

C ,16

.6A MA

X

AT-PWR3202

12V

DC

,16.6A

MAX

198

RPS O

UTPU

T A2

12VDC

RPS O

UTPU

T A1

12VDC

AC INPUT A

2/A1

100 - 240

VAC

~

ON
OFF

ON
OFF

A1

A2

199

RPS OUTPU

T A2

12VDC

RPS OUTPU

T A1

12VDC

AC INPUT A2/A

1

100 - 240

VAC

~

ON

OFF

ON
OFF

A1

A2

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Allied Telesis Models

All Allied Telesis Other