Allied Telesis 4000 Series - Manual

Allied Telesis 4000 Series

Allied Telesis 4000 Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
Page: / 22

Table of Contents:

  • Page 2 – Enabling and installing this Release; Level 1; This issue will seldom appear, and will cause minor inconvenience.; Level 4
  • Page 3 – No level one issues; Level 2
  • Page 4 – No level four issues
  • Page 5 – Enhancements
  • Page 8 – Level 3
  • Page 11 – Software maintenance version sb275a03 was not released.
  • Page 18 – SYSLOG
  • Page 19 – queryresponseinterval; Disabling Query Solicitation and Display Settings; To see whether query solicitation is on or off, use the command:
  • Page 20 – Software Maintenance Release Note; The original syntax was:
  • Page 21 – Figure 1
Loading the manual

Software Maintenance Release Note

Software Version sb275a05
For SwitchBlade 4000 Series Switches

Introduction

This software maintenance release note lists the issues addressed and
enhancements made in maintenance version sb275a05 for Software Release
2.7.5A on existing models of SwitchBlade series switches. Release file details
are listed in

Table 1

.

This maintenance release note should be read in conjunction with the
following:

the documentation you received with Software Release 2.7.5A

the SwitchBlade Document Set for Software Release 2.7.3 (Document
Number C613-03100-00 REV A), available from:

www.alliedtelesis.co.nz/documentation/documentation.html

Caution:

Using a software maintenance version for the wrong model may cause

unpredictable results, including disruption to the network.

Information in this release note is subject to change without notice and does not
represent a commitment on the part of Allied Telesis Inc. While every effort has
been made to ensure that the information contained within this document and
the features and changes described are accurate, Allied Telesis Inc. can not
accept any type of liability for errors in, or omissions arising from the use of this
information.

Table 1: Release file details for release sb275a05

Maintenance Release Date

7 February 2007

Compressed Release File Name

sb275a05.rez

Compressed Release File Size

3764560

GUI Resource File Name

d_sb8e29.rsc (8-slot chassis)

d_sb4e29.rsc (4-slot chassis)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Enabling and installing this Release; Level 1; This issue will seldom appear, and will cause minor inconvenience.; Level 4

2 Enabling and installing this Release Software Maintenance Release Note Version sb275a05 C613-10464-00 Rev H Some of the issues addressed in this Maintenance Release Note include a level number. This number reflects the importance of the issue that has been resolved. The levels are: Enabling and in...

Page 3 - No level one issues; Level 2

Software Version sb275a05 3 Version sb275a05C613-10464-00 Rev H Features in sb275a05 Software maintenance version sb275a05 includes all resolved issues and enhancements in earlier 2.7.5A versions, and the resolved issues and enhancements in the following tables. Level 1 No level one issues Level 2 C...

Page 4 - No level four issues

4 Features in sb275a05 Software Maintenance Release Note Version sb275a05 C613-10464-00 Rev H Level 3 Level 4 No level four issues CR00015071 IP Gateway 2 Routing over a PPP interface could fail if the switch had a default route out an Ethernet port. The default route switched all packets, even thos...

Other Allied Telesis Models

All Allied Telesis Other