Page 3 - Table of Contents
516512 1 Table of Contents Section 1 – Safety Information .........................3 Locating an Authorized Servicer .............................4 Section 2 – Introduction ....................................5 Customer Service .....................................................5Nameplate Location...
Page 5 - DANGER; WARNING
516512 3 Section 1 Safety Information Throughout this manual and on machine decals, you will find precautionary statements (“CAUTION,” “WARNING,” and “DANGER”) followed by specific instructions. These precautions are intended for the personal safety of the operator, user, servicer, and those maintai...
Page 6 - Locating an Authorized Servicer; reconnected to ensure that the dryer is properly grounded.
4 516512 Section 1 Safety Information NOTE: The WARNINGS and IMPORTANT INSTRUCTIONS appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when installing, maintaining or operating the dryer. Always cont...
Page 7 - Customer Service
516512 5 Section 2 Introduction Customer Service If literature or replacement parts are required, contact the source from whom the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor. For technical assistanc...
Page 8 - Model Identification; Information in this manual is applicable to these dryers:
6 516512 Section 2 Introduction Model Identification Information in this manual is applicable to these dryers: Dryer Model Homestyle Electric Heat Gas Heat LEB07A*F1709 X X LEG37A*F4350 X X LEH37A*F3300 X X LEK37A*F4350 X X LES17A*F X X LES17A*F1500 X X LES17A*F3000 X X LES17A*F4500 X X LES33A*F4562...
Page 9 - How Your Dryer Works
516512 7 Section 2 Introduction How Your Dryer Works The dryer uses heated air to dry loads of laundry. When the motor is started, the exhaust fan pulls room temperature air in through louvers at the rear of the dryer and over the heat source (burner flame for gas and heating element for electric). ...
Page 10 - Notes
Page 11 - Section 3; MOTOR DOES NOT RUN; POSSIBLE CAUSE
516512 9 To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• Whenever ground wires are remov...
Page 12 - CYCLES ON MOTOR THERMAL PROTECTOR
10 516512 Section 3 Troubleshooting To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• When...
Page 13 - MOTOR RUNS BUT CYLINDER DOES NOT TURN
516512 11 Section 3 Troubleshooting To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• When...
Page 14 - HEATING ASSEMBLY DOES NOT HEAT OR BURNER DOES NOT IGNITE
12 516512 Section 3 Troubleshooting To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• When...
Page 16 - HEATER ASSEMBLY OR BURNER SHUTS OFF PREMATURELY
14 516512 Section 3 Troubleshooting To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• When...
Page 17 - HEATER ASSEMBLY OR BURNER DOES NOT SHUT OFF
516512 15 Section 3 Troubleshooting To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• When...
Page 18 - TIMER DOES NOT ADVANCE IN AUTOMATIC CYCLE
16 516512 Section 3 Troubleshooting To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• When...
Page 21 - Section 4; GROUND WIRES FROM TERMINAL BLOCK TO REAR BULKHEAD AND FROM REAR
516512 19 To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• Whenever ground wires are remo...
Page 23 - Section 5; CONTROL HOOD ASSEMBLY
516512 21 To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• Whenever ground wires are remo...
Page 24 - To Test Timer Contacts:
22 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 25 - FABRIC SELECTOR SWITCH
516512 23 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 26 - GRAPHIC PANEL, CONTROL HOOD AND CONTROLS
24 516512 Section 5 Service Procedures Figure 5 GRAPHIC PANEL, CONTROL HOOD AND CONTROLS D378PE3A SCREWS TOP COVER FABRIC SELECTOR SWITCH SIGNAL SCREW SCREW SCREW CONTROL HOOD REAR PANEL SUPPORT CONTROL PANEL CABINET TOP SWITCH KNOB ASSEMBLY TIMER KNOB ASSEMBLY GRAPHIC PANEL END CAP RIGHT END CAP LE...
Page 27 - CONTROL PANEL AND CONTROLS
516512 25 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 28 - b. Remove screw from end of lint filter. Refer to; LOADING DOOR AND DOOR HINGE; b. Remove screws holding loading door to hinges.; SECURED LINT FILTER
26 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 29 - INNER AND OUTER DOOR PANELS AND; a. Remove four screws holding door assembly to
516512 27 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 30 - Reversing Door Procedure; Remove all nine screws.
28 516512 Section 5 Service Procedures Reversing Door Procedure The dryer door is completely reversible. To reverse door proceed as follows: Figure 9 DRYxxS D382S D377S D378S D314S D315S A B D316S B A D312S D311S 7 8 9 1 2 3 4 5 6 Remove all nine screws. Pull bottom of door liner out, then pull down...
Page 31 - b. Remove screw holding door strike and bracket
516512 29 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 32 - FRONT PANEL AND PANEL SEAL
30 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 35 - BURNER SYSTEM COMPONENTS; Coil Tolerance Readings
516512 33 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 36 - SILICON CARBIDE IGNITION SYSTEM
34 516512 Section 5 Service Procedures Figure 13 SENSOR LEAD-IN PIPE HEATER BOX ATTACHING SCREWS HEAT SHROUD SENSOR TERMINALS TAB UNION NUT NIPPLE GAS VALVE HOLDING AND BOOSTER COIL SECONDARY COIL IGNITER WIRES DISCONNECT BLOCK BURNER TUBE SCREW BURNER HOUSING SENSOR ATTACHING SCREW SCREW SHUT-OFF V...
Page 37 - To Test Electrical Circuit to Ignition System
516512 35 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 38 - GAS VALVE FOR SILICON NITRATE IGNITION
36 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 39 - To Test Ignition Control Grounding; Set test meter to read Ohms and put meter
516512 37 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 40 - BURNER HOUSING AND HEAT SHROUD; GAS MODELS WITH SILICON CARBIDE
38 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 41 - To Test Heater Assembly; Resistance Reading
516512 39 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 42 - To Test Thermal Fuse:
40 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 43 - MOTOR AND EXHAUST ASSEMBLY
516512 41 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 44 - i. Pull assembly forward and disengage the; j. Rotate the assembly 90° counterclockwise and; slide out through front of dryer.; k. Motor pulley and idler pulley assemblies; CORRECT; INCORRECT
42 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 48 - YES
46 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 50 - FRONT BULKHEAD ASSEMBLY; a. While supporting the access panel, remove two
48 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 51 - e. Disengage belt from motor and idler pulley.
516512 49 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 52 - CYLINDER ASSEMBLY
50 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 53 - h. Carefully remove cylinder out through front of
516512 51 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 56 - REAR BULKHEAD AND HEATER DUCT
54 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 57 - (1) Remove two screws holding element and
516512 55 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 58 - TERMINAL BLOCK OR POWER CORD; (2) Gently lower the access panel to disengage
56 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 59 - wire to rear bulkhead. Refer to Figure 36.
516512 57 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 62 - (c) Remove screw holding exhaust duct to
60 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 65 - j. Remove two screws holding motor mounting; k. Rotate the assembly counterclockwise 90° and; slide out front of machine.
63 516512 Section 5 Service Procedures To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• W...
Page 67 - Section 6; a. Place dryer in position, adjusting the legs until
516512 65 To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• Whenever ground wires are remo...
Page 71 - Section 7
516512 69 To reduce the risk of electric shock, fire, explosion, serious injury or death:• Disconnect electric power to the dryer(s) before servicing.• Close gas shut-off valve to gas dryer(s) before servicing.• Never start the dryer(s) with any guards/panels removed.• Whenever ground wires are remo...
Page 73 - Section 8; WIRING DIAGRAMS AND SCHEMATICS
516512 71 Failure to install, maintain, and/or operate this machine according to the manufacturer's instructions may result in conditions which can produce bodily injury and/or property damage. W030 WARNING Section 8 Wiring Diagrams WIRING DIAGRAMS AND SCHEMATICS FOUND ON THE FOLLOWING PAGES ARE FOR...