Loading the manual

Brn

Red

Gray

Brn
Red

Gray

- INSTRUCTIONS -

WIRING DIAGRAM:

All Call Adaptor for NHX System

1 NH-50AC for All Call up to 49 Stations, 2 NH-50AC for up to 79 Stations

NHX-80X

11
12

~

21
22

~

31
32

~

41
42

~

51
52

53
54
55
56

NOTES:
1. The application requires one of the station buttons to be
used for All Call.
Therefore, the standard system can have up to 49 stations,
and the expanded system can have up to 79 stations.
2. Only wiring concerning the NH-50AC is shown here. For
complete installation and wiring information, please see the
NHX Installation instructions.

PS-1225UL

+

-

Trunkage Line

Connection

Terminals

Some applications for Nurse Call systems require All Call. By including this adaptor, a station button on the master
can be used to call all of the patient stations simultaneously. An additional wire is required to each patient station.

NOTE: An NHX system installed with an NH-50AC included does not carry the UL 1069 listing.

NHX

Nurse Call System

11

1B

12

1R

BL

21

2B

22

2R

BL

31

3B

32

3R

BL

41

4B

42

4R

BL

51
52

5B

A1

5R

A2

BL

P3
P4
D5
D6

X1

+
-

AUX

NH-50AC

Brn

Red

Blk

Trunk #1

Patient Stns*

Brn

Red

Blk

Trunk #2 Patient

Stns*

Trunk #5

Patient Stns*

Connections to 2nd NH-50AC:
X1: Control wire
A1: Audio
A2: Audio
12V+: Power
12V-: Ground

Brn

Red

Gray

Brn

Red

Gray

* Patient Stations for All Call:

Model NH-1SA/AC or NH-2SA/AC.
Additional BLACK wire coming from back of
unit connects to Gray wire of trunkage cable,
and to BL terminal of NH-50AC.

IMPORTANT:
Connection from CCU trunk line terminals determines which
column the All Call button will be on. (e.g. This example
shows trunk line 5, so All Call button will be on column 5 of
master station. Dip switch settings on the NH-50AC will
designate the All Call button position (1~10).

Pg. 1

Org

Yel

Grn

Blu

Brn

Red

Blk

Trunk #3 Patient

Stns*

Trunk #4 Patient

Stns*

Brn

Red

Gray

Brn

Red

Blk

Brn

Red

Blk

Org

Yel

Grn

Blu

Jumper to
Negative of
one PS-2420UL

0708

To AUX input of 2

nd

NH-50AC

To 2

nd

NH-50AC

(For 50-79 station system)

}