Aiphone NE-NVP-2DC - Manual

Aiphone NE-NVP-2DC

Aiphone NE-NVP-2DC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

+

-

- INSTRUCTIONS -

The NE-NVP-2DC is a vandal proof sub station designed for use with the NDR or NDRM system.
It is constructed of 11 gauge carbon steel with a white powder-coated finish. The NE-NVP-2DC can
be flush or surface mounted and includes tamper proof screws and a wrench for installation.

WIRING DIAGRAM:

Vandal Proof Sub Station with Standard Call Button

and Red Emergency Call Button

Equipped with DPDT Contacts

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071

NE-NVP-2DC Instr.

35213 Rev. 6

0710JD

SPECIFICATIONS:

Power Source:

Supplied by master station

Speaker:

20 ohms, 2-½" diameter, water proof and puncture resistant, 2.4 oz. ceramic magnet

Call Button:

SPST, normally open push button. Red button: Activates DPDT N/O contacts (ORG/YEL pairs).
DPDT Relay Contacts: 6A @ 125V AC or 6A @ 30V DC. Min. 25,000 operations

Faceplate:

11 gauge carbon steel with powder-coated white baked epoxy finish

Call Annunciation:

Standard call button at sub latches call at NEM master until answered.
Red emergency button is "push-on, push-off", which activates or deactivates DPDT contacts and
red LED. "Push-on" activates relay and LED, "push-off" deactivates them.

Communication:

Hands free at sub. Master is push-to-talk or VOX with handset.

Terminal Definitions:

RED: Station #
BLACK: to "E" (Common)
WHITE: to "H" (12 VDC - Powers DPDT contacts and LED)

Wiring:

Communication and standard call: 3 conductors homerun; or 2 common plus 1 individual per
sub, looped through each sub. Shielded cable is recommended.
Use Aiphone #822203 or #821803 for homerun wiring, #822206 for up to 4 stations.

DPDT contacts require 4 additional wires from each sub station.

Wiring Distance:

420' with 22AWG; 1,000' with 18AWG (standard call and communication).

Dimensions (H x W x D): NE-NVP-2DC alone: 7-1/2" x 5-1/2" x 2". With SBX-NVP: 8-5/8" x 6-5/8" x 2-1/4"

NDR/NDRM

Master

PS-2420UL

NOTES:

1. Do not cut the green jumper on the circuit board unless an external call-placed lamp is installed at the sub station.
2. Red Duress call button on sub station provides two sets of alternate action N/O contacts (Orange/Yellow pairs).

Both contacts are activated by push on/push off function of Duress button. (Open when off, closed when on.)

3. NE-NVP-2DC flush mounts into a 3-gang masonry type box (Raco #692, 697, or equivalent.)
4. Surface mount box for NE-NVP-2DC is model SBX-NVP, sold separately.

Contact #1

Contact #2

Contact #1

Contact #2

NE-NVP-2DC

Contact #1

Contact #2

Toll Free Technical Support:

1-800-692-0200

E-mail [email protected]

Red

Wht

Blk

Blu

Org
Org

Yel
Yel

Green
jumper

(Do not cut)

Red

Wht

Blk

Blu

Org
Org

Yel
Yel

Green
jumper

(Do not cut)

Red

Wht

Blk

Blu

Org
Org

Yel
Yel

Green
jumper

(Do not cut)

1
2
3
~

20

H

E

+

-

NE-NVP-2DC

NE-NVP-2DC

0710