Aiphone MYW-P10L - Manual
Aiphone MYW-P10L – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
- INSTRUCTIONS -
10 Camera Adaptor for LEF/LDF System
WIRING DIAGRAM:
Pg. 1
The MYW-P10L adaptor allows up to 10 2-wire video door stations to be used with the LEF series Master
Sentry System. MY or MK PanTilt series video door stations may be used with the MYW-P10L. CCTV
cameras may be connected through the MYW-P10L using the MYW-MD/B adaptor. Door release is
available through the intercom system (LEF or LDF only).
NOTES:
1. The MONITOR button, Auto-Scan
Duration, and Monitor Receive
Volume switches on the front of the
unit are non-functional.
2. Diodes shown
must
be used
when using RY-PA door release
relays. They are 1N4007, and are
included in the box with the unit.
3. When initializing the MYW-P10L
with CCTV cameras,
a constant call
tone will be heard on the LEF
master for approx. 1 minute
during this process.
To avoid this,
unplug the PS-1225UL for the LEF
system before turning on the MYW-
P10L, then plug back in when the
initialization is complete.
The
constant tone will also be heard if
the MYW-P10L loses power, or if
it is turned off.
4. Only wiring concerning the MYW-
P10L is shown here. For complete
installation and wiring information,
please see the standard LEF
instructions.
1205
MK-DAC
RY-PA
RY-PA
RY-PA
RY-PA
Ye
llow
Ye
llow
Ye
llow
Ye
llow
B
lack
Black
Black
Black
To Strike
& Power
#1
To Strike
& Power
#2
To Strike
& Power
#3
To Strike
& Power
#4
Ye
llow
B
lack
To Strike
& Power
#5
RY-PA
MK-DAC
MK-DBC
MK-DBC
MK-DGC
Any MK-series
video door station
is compatible with
this system.
B1
1A1
B2
1A2
2A1
U1
2A2
U2
3A1
3A2
+18V
-18V
4A1
4A2
5A1
5A2
~
10A1
10A2
1
2
3
4
5
6
7
8
9
10
E
+12V
-12V
K1
K2
K3
K4
K5
~
K10
MYW-P10L
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
1
2
3
4
5
6
7
8
9
10
C
E
R
Y
+
-
L
K1
K2
K3
K4
K5
~
K10
1
2
3
4
5
6
7
8
9
10
C
E
R
Y
+
-
L
K1
K2
K3
K4
K5
~
K10
LEF-10
LEF-10
+
-
PS-1225UL
A1
A2
B1
B2
U1
U2
+
-
B1
B2
A1
A2
U1
U2
+
-
MYH-CU
MYH-CU
+
-
PS-1820UL
INSIDE MYW-P10L CHASSIS
EXTERNAL TERMINAL BLOCK
MYW-P10L TERMINAL DEFINITIONS:
Found inside MYW-P10L
n
A1
Input from MY/MK Series
n
A2
video door station
B1
Video signal output
B2
to monitors
U1
Video activation
U2
to monitors
18V+
Positive 18V DC
18V-
Negative
N1,N2
Unused
Found in external terminal box
1 ~ 10
Audio communication
E
Common communication
12V+
Positive 12V DC
12V-
Negative
K1 ~ K10 Video control terminals
To: Monitor TV
and/or Time-Lapse
VCR, ect.
(525) line only
CN-9
*When using door release relays: Install cathode side of
supplied 1N4007 diodes directly to K terminals of MYW-P10L,
and connect black wire of RY-PA to anode side of diode.
Do not install diodes on K terminals at the LEF master station.
*
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.