PHONE JACK TERMINAL BLOCK WIRING
With
KX-TA62460
Doorphone card (Analog):
D1 = 1 (Green)
E = 2 (Red)
D2 = 3 (Black)
E = 4 (Yellow)
With
KX-TD160
Doorphone card (Digital):
D1 = 2 (Red)
E = 1 (Green)
D2 = 4 (Yellow)
E = 3 (Black)
With
KX-TD161
Doorphone card (Digital):
D1 = 1 (Green)
E = 2 (Red)
D2 = 4 (Yellow)
E = 3 (Black)
- INSTRUCTIONS -
This monitor allows one or two MK video door stations to be used for video door answering, where the
communication is through a Panasonic® telephone system and the video appears on the Aiphone
monitor(s). The MY-CU-PH/B integrates MK PanTilt door stations with Panasonic's KX-T series
systems. (Works with KX-TA Advanced Hybrid series and KX-TD Digital Super Hybrid series.)
MY-CU-PH/B
Video Monitor
MK Video Door Answering with Panasonic® Phone System
MY-CU-PH/B TERMINAL DEFINITIONS:
1A1
2-Wire connection
1A2
for Door Station #1
2A1
2-Wire connection
2A2
for Door Station #2
B1
Video out to
B2
sub monitors
U1
Control wires
U2
Control wires
+
Positive 18V DC
-
Negative
To Panasonic Phone System:
D1
Door 1 call-in & audio
D2
Door 2 call-in & audio
E
Common audio
Special
Order
Products
WIRING DIAGRAM:
*VIDEO DOOR STATIONS:
Any Aiphone MK or MY Series video door
station can be used:
-MK-DAC: Surface mount, black
-MK-DBC: Semi-flush mount, black
-MK-DGC: Semi-flush mount, metal cover
-MK-DGV: Semi-flush mount, vandal
proof, stainless steel cover
-MK-DS/B: Surface mount, fixed camera,
Black
1A1
1A2
2A1
2A2
B1
B2
+
-
U1
U2
D1
E
D2
MY-CU-PH/B
MK-DBC*
A1
A2
PS-1820UL
+
-
MK-DBC*
A1
A2
A1
A2
B1
B2
+
-
U1
U2
MYH-CU
B1
B2
A1
A2
+
-
U1
U2
MYH-CU
Pg. 1
1 2
3 4
Modular cord
from terminal
block to Door
Adaptor in
Panasonic KSU
DA1
DA2
+
-
DV+
DV-
MYW-MD/B
VIDEO OUTPUT TO CABLE
DISTRIBUTION OR CCTV MONITOR:
Use Aiphone MYW-MD/B Demodulator,
wired with 4 conductor, 18 AWG wire from
the MY-CU-PH/B monitor or last MYH-CU
in the system. Output is a standard 1V
peak-to-peak video signal.
Move jumper to
bottom 2 pins
Raw video output
DV+ to core of Coax
DV- to shield of coax
PS-1820UL
+
-
SPECIFICATIONS:
Power Source:
18V DC.
Use one PS-1820UL for every three monitors.
Consumption:
MY-CU-PH/B Standby: 0.12A; Max. 0.9A
MYH-CU Standby: 0A; Max .4A
Communication:
Through Panasonic® Telephone system
Hands free at door station
Calling:
Monitors activate and Panasonic phones ring
Video Monitor:
4" direct view flat CRT
Scanning lines:
525 lines
Dimensions (HxWxD): 8-14"" x 6" x 2"
Weight:
MY-CU-PH/B: 2.2 lbs.
MYH-CU: 1.98 lbs
Updated 07/2002
(Analog wiring shown)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.