- INSTRUCTIONS -

The MKW-M adaptor converts a standard CCTV camera's signal to a 2-wire signal, compatible with the MK-1GD,
MK-2MCD, and MY series Black & White Video systems. This allows the utilization of a black & white CCTV
camera and a separate audio door station (JA-D)* to be used in place of an MK video door station. A motion
detector or other activation device can be connected to the Sensor input to trigger the system. The CCTV camera
can also be connected to a standard CCTV system for continual viewing and/or recording. The unit is equipped
with a relay output to trigger an external device, such as a DVR or video switcher whenever the audio and video
to the Aiphone monitor is on.

Video Modulator with Audio Door Station and CCTV Interface

A1
A2

B1
B2

+

-

MK or MY Monitor

or Adaptor*

MASTER

A1
A2

AUDIO

1
2

VIDEO IN

VIDEO OUT

SENSOR

NC
NC

RELAY

NO
NO

MKW-M

PS-1820UL

+

-

Pg. 1

WIRING DIAGRAM:
MKW-M Modulator for Standard CCTV camera and Audio Only door station

OUT

IN

VIDEO

OFF ON

75 OHM

AIPHONE

SENSOR RELAY MASTER AUDIO

NC NC NO NO A1 A2 1 2

1
2

CCTV Camera

75 Ohm, 1V Peak-to-peak
(Independently powered)

Constant video output for
CCTV monitor, DVR, etc.

Normally Open contact for
remote device activation
(i.e. video switcher, DVR, etc.)

When VIDEO OUT is connected, set

75 Ohm switch to OFF position.

NOTES:

1. JA-D is the only compatible door

station with this unit.

2. Video Output is optional. If not

used, set 75 Ohm switch to ON
position.

3. SENSOR input can be used

only if there is no JA-D door
station connected. When used,
the camera will turn on when the
sensor device is activated.

JA-D*

(Optional, only if Sensor

input is not used)

Remote Activation*

(Optional, only with no JA-D

installed)

* Signaling device that provides a

Normally Closed momentary

contact.

*COMPATIBLE MODELS:

MK-1GD

MK-2MCD
MY-CU
MYW-P1L
MYW-P3L
MYW-P10L