WIRING DIAGRAM:
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
MKW-DK Instr.
0102bkjd
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
E-MAIL: [email protected]
+
-
Power
Supply
1A1
1A2
L
L
+
-
Aiphone Monitor
Motion Detector*
White
Yellow
*Must be installed within
2' of door station.
Installation Guidelines:
1. The motion detector must provide
a normally open momentary contact
. A Photelectric beam, pressure
pad, or remote call button can also be used to activate the video door station.
2. MKW-DK must be installed within 2 feet of video door station.
3. The MKW-DK can be used to connect a motion detector to all MK, MY, KA, and KC series video door
stations.
4. The above diagram is representative of the installation of the MKW-DK to an Aiphone video system.
Terminal definitions will vary depending on the system being installed.
5. The MKW-DK is not compatible with the KB-DAR. Contact Aiphone for information on model KB-DAR-M
(KB-DAR with input for Motion Detector).
Note:
For complete system installation, please refer to the instruction manuals included with the video system.
Door Strike
PT-1210N
(AC Transformer)
MKW -
DK*
MKW-DK
Motion Detector Interface Adaptor for Video Door Stations
Special
Order
Products
The MKW-DK Adaptor allows any standard
motion detector or activation device with a normally open
contact
to be interfaced with any 2-wire Aiphone Video Door Station (except KB-DAR). When the
activation device is tripped, the camera will turn on, and a chime (or tone) will be heard at the inside
monitor station(s), indicating that there is some activity near the door station location.
- INSTRUCTIONS -
A1
A2
Video Door
Station
* Or any signaling
device that provides a
a normally open
momentary dry closure.
Motion Detectors with N/O Contacts:
Detection Systems DS720I
Pulnix 6612
Intellisense 8140S
Ademco 1998PI
Sentrol AP750
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.