- INSTRUCTIONS -

The LE-B

n

entry stations are used to selectively call from 2 up to 10 master stations (or groups

of masters). For surface mount applications, include the VC-BBX surface mount box. The
system has one communication path.

WIRING DIAGRAM:

Selective Call Entry Station for Open Voice Systems

Use with:

LEM-1DL/C, LEF, LAF-C, or LDF Masters

Individual Components for System with LE-B2~LE-B10 Entry station:

C-ML/A

Wall mount master with door release button

SKK-620

6V DC power supply, 1 per C-ML/A

LEM-1DL/C Desk mount master station with door release and occupied lamp
PT-1210N 12V AC transformer, 1 per LEM-1DL/C
LEF-

n

Master station, 3, 5, or 10-call sizes

(No door release on LEF-3)

LAF-

n

C/CA

Console master station, 20 and 40 stn. sizes (no door release)

LDF-

n

C/CA

Console master with selective door release, 20 and 40 stn. sizes

PS-1225UL

12V DC power supply, 1 per system (LEF/LAF-C/CA/LDF-C/CA only)

STATION MOUNTING:

LE-B

n:

Flush mount with backbox included.

Cutout dimensions: 9-1/16" H x 6-1/8" W x 2-11/16" D
Surface mount:

Aiphone model VC-BBX

Unit dimensions:

10-3/8" H x 7-1/2" W x 2-1/16" D

E

-

+

R

1

K1

L

LEF-5 #1

LE-B6

E

-

1

2

3

4

5

6

NOTES:

1. In this example, the LE-B6 sub station rings in on station #1 of each master station. It can be wired to any unused
station number .
2. Only wiring concerning the LE-B6 is shown here. For complete wiring information, please see the standard LEF
instructions. If additional master stations are to be installed in each office/suite, wire them per the standard instructions.

E

-

+

R

1

K1

L

E

-

+

R

1

K1

L

E

-

+

R

1

K1

L

-

+

PS-

1225UL

LE-B2~6 Terminal Definitions:

E

Common communication

-

Negative, common call signal

1~6

Selective call/communication
terminal for each call button
located on the back of speaker unit

LE-B10 Terminal Definitions:

E

Common communication

-

Negative, common call signal

1-10

Selective call/communication
terminal for each call button
located on the back of each switch

Wires:

(Used only for backlight illumination lamp)

Red

+12VDC (connect to + of PS-1225UL)

Black

(-) for lamp (connect to - of PS-1225UL)

Remove E/-

jumper on all

masters.

E

-

+

R

1

K1

L

E

-

+

R

1

K1

L

LEF-5 #2

LEF-5 #6

LEF-5 #5

LEF-5 #4

LEF-5 #3

LE-B6 WITH LEF-5 MASTER STATIONS

RY-PA

~
~

AC Power

Door Strike

Blk

Yel

Pg. 1

1205

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Aiphone Models

All Aiphone Other