Aiphone LDF-40CA - Manual

Aiphone LDF-40CA

Aiphone LDF-40CA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

- LDF SUPPLEMENT TO LAF-C/CA INSTRUCTIONS -

The LDF Loudspeaker Intercom and External Control System is designed for communication between a central master
station and remote intercom stations.

The LDF is an expanded feature version of the LAF-C/CA system.

All

information regarding installation other than the external control functions is included in the LAF-C/CA instructions. In
addition to communication to remote locations, external devices can be activated, such as activating a CCTV camera
when the associated sub station is selected, selectively controlling the corresponding door strike or maglock, or both.

WIRING DIAGRAM: SYSTEM USED FOR CCTV CAMERA CALL-UP

LDF

LDF Loudspeaker Master Station with External Control Capability

LDF-20C

LDF-40C

LDF-20CA

LDF-40CA

Individual Components for System:

LDF-

n

C

Master station with selective contact output capability (20, 40)

LDF-

n

CA

Master station w/handset and selective contact output capability (20, 40)

LD-20AS

20-call Add-on Selector with selective output capability

LD-40AS

40-call Add-on Selector with selective output capability

RY-PA

Relay for selective output (1 per station requiring external contact)

PS-12C

12V DC, 1A Power Supply

LE-series

Any model sub station with LE-prefix

LS-NVP

Vandal proof sub station (add SBX-NVP for surface mount)

IMPORTANT:

1.

RY-PA must be used for each additional contact to
isolate AC voltage from the intercom circuit.

2.

Extra contact connections and L are on separate
terminal block. LDF-40C/CA has two terminal blocks.

S p e c i a l

O r d e r

P r o d u c t s

1
2
3

~

20

E

-

+

-

LDF-20CA

+

-

PS-12C

LS-NVP

Red

Blk

Grn

Red

Blk

Grn

LS-NVP

1

2

3
~
20 L

1

E

-

LE-DA

RY-PA

#1

RY-PA

#2

RY-PA

#3

BLK

BLK

BLK

YEL

YEL

YEL

External

Terminal Block

CONSTANT CLOSURE:

Normally Open contacts remain closed as
long as master has sub station selected.

Constant Closure for Station #1

Pg. 1

Constant Closure for Station #2

Constant Closure for Station #3

LDF TERMINAL DEFINITIONS:

+

Positive 12V DC input, and constant closure output

-

Negative

1~40

Station number

E

Common communication

R

Occupied LED control

L

Positive output for selective closure
(Located on terminal block)

NOTE:

Leave jumper between E & - on master
and subs when using 2 conductor
homerun wiring IN SINGLE MASTER
SYSTEM ONLY. Jumper BLK/GRN
wires at LS-NVP in 2-wire system.

1

L

2

RY-PA

#1

BLK

+

-

RY-PA

#2

LDF Master

RY-PA

#1

RY-PA

#2

BLK

BLK

BLK

YEL

Momentary closure #1

YEL

Constant closure #1

YEL

Momentary
closure #2

YEL

Constant
closure #2

Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
2 Diodes (1N4001)

DUAL FUNCTIONS FROM EACH CHANNEL:

Terminal Block