Agilent E3617A - Manual

Agilent E3617A

Agilent E3617A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
Page: / 47

Table of Contents:

  • Page 2 – SAFETY SUMMARY
  • Page 3 – Table of Contents
  • Page 4 – GENERAL INFORMATION
  • Page 5 – SPECIFICATIONS
  • Page 6 – Full load No load; DC ISOLATION; INSTALLATION; INITIAL INSPECTION; Figure 1. Outline Diagram; INPUT POWER REQUIREMENTS
  • Page 7 – Power Cord; OPERATING INSTRUCTIONS; INTRODUCTION; Figure 3. Front-Panel Controls and Indicators; LINE Switch: Pressing this switch turns the supply on, or off.; TURN-ON CHECKOUT PROCEDURE; On Checkout
  • Page 8 – OPERATING MODES; LOCAL OPERATING MODE; Constant Voltage Operaton; CONNECTING LOADS
  • Page 9 – REMOTE OPERATING MODES; Remote Voltage Sensing; Figure 5. Remote Voltage Sensing; Remote Analog Voltage Programming
  • Page 10 – MULTIPLE-SUPPLY OPERATION; NORMAL PARALLEL OPERATION; Figure 8. Normal Parallel Operation of Two Supplies; AUTO-PARALLEL OPERATION
  • Page 11 – Figure 9. Auto-Parallel Operation of Two Supplies; Figure 10. Auto-Parallel Operation of Three Supplies; NORMAL SERIES OPERATION; Figure 11. Normal Series Operation of Two Supplies
  • Page 12 – AUTO-SERIES OPERATION; Total output voltage to ground must not exceed 240 Vdc.; It is recommended to connect a 0.1; Figure 12. Auto-Series Operation of Two Supplies
  • Page 13 – AUTO-TRACKING OPERATON; Figure 14. Auto-Tracking Operation of Two Supplies
  • Page 14 – LOAD CONSIDERATIONS; PULSE LOADING; Figure 16. Reverse Current Loading Solution; OUTPUT CAPACITANCE; Figure 17. Recommended Protection Circuit for
  • Page 15 – SERVICE INFORMATION; PRINCIPLES OF OPERATION
  • Page 16 – MAINTENANCE; Test Equipment Required
  • Page 17 – PERFORMANCE TESTS; Measurement Techniques; Figure A-3. Current Monitoring Resistor Connections
  • Page 18 – Load Transient Response Time
  • Page 19 – Figure A-5. Load Transient Response Time Waveform; Figure A-6. CV PARD RMS Measurement Test Setup
  • Page 20 – Setup
  • Page 21 – Figure A-8. CC PARD RMS Measurement Test Setup
  • Page 22 – Ammeter and CC Set Calibration; Voltmeter and OVP Set Calibration; TROUBLESHOOTING; Overall Troubleshooting Procedure
  • Page 23 – Overvoltage Protection Circuit Troubles
  • Page 26 – REPLACEABLE PARTS
  • Page 38 – Manual Supplement; This supplement updates the following document:
  • Page 39 – N O T E; Constant Voltage Mode; Programming Voltage Common to the Plus output; Set the CV switch down on the rear panel, and all others up.; Model
  • Page 40 – Alternative Voltage Programming Using Resistors; Programming Voltage Common to the Plus Output
  • Page 41 – F capacitor
  • Page 42 – Constant Current Mode; Constant Current with Voltage Programming; Set the CC switch down the rear panel, and all others up.; Constant Current with Current Programming
  • Page 43 – Figure 6; Set the CC switch down, and all others up.; Current Monitoring
  • Page 44 – Remote Resistor Programming Connections; Figure 7; is the power supply output voltage.
  • Page 45 – Remote Resistor Programming, Constant Current; Figure 8; Set the CC switch down on the rear panel, and all others up.; is the power supply output current.
  • Page 46 – For consumer; EXCLUSIVE REMEDIES
  • Page 47 – DECLARATION OF CONFORMITY; According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014; This declaration covers all options of the above product(s).; Date; Bill Darcy / Regulations Manager
Loading the manual

Agilent E361xA 60W BENCH SERIES DC POWER SUPPLIES

OPERATING AND SERVICE MANUAL FOR MODELS:

Agilent E3614A
Agilent E3615A
Agilent E3616A
Agilent E3617A

Manual Part No. 5959-5310

April 2000

Edition 8

1-1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY SUMMARY

1-2 SAFETY SUMMARY The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and inten...

Page 3 - Table of Contents

1-3 Table of Contents SAFETY SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1...

Page 4 - GENERAL INFORMATION

1-4 GENERAL INFORMATION INTRODUCTION This manual describes all models in the Agilent E361xA 60WBench Power Supply family and unless stated otherwise, theinformation in this manual applies to all models. SAFETY REQUIREMENTS This product is a Safety Class I instrument, which meansthat it is provided w...

Other Agilent Models

All Agilent Other