1 Page 1
Page: / 1
Loading the manual

USE

Final Installa

tion

Figur e 7

2. Ducting

Put one end of the 4 inches diameter

ventiduct into the vent hole. Insulate and

seal space around the hole .

Note: Since the length of the duct is 5

feet, make sure that from the center

of installation position there should

be a distance within 5 feet to the vent.

If it requires more than 5 feet of

distance, purchase an extension

ventiduct from your local agent.

3. Locating the heater

For the purpose of obtaining best heating effect, from the lamps there should be a 7 feet~ 8 feet

overall height to ground.

Note: The ceiling joists must be strong.

4. Remove the fascia

Remove all lamps from the heater. Unclip four fascia-retaining springs inside the housing.

Remove the fascia.
Note: Do not force when removing the infrared lamps.

5. Take out three screws from the wire cover and remove the wire cover

.(Figure2)

6. Remove one of the knockouts according to the need.

7. Fix a clamp connector or wire holder to the opened

knockout.

2. Fix the brackets

2. Replace the fascia.

3. Replace the lamps.

Ensure the lamps are screwed sufficiently to make good electrical contact. Clean the globes

and fascia.

Our bathroom master uses the infrared lamps as a source of heat. It also combines the

functions of exhausting and lighting.

1. Heating

2 lamps: Turn on/off ' ' or ' ' button.

4 lamps: Turn on/off ' ' and ' ' button.

This model is supplied with 2 groups of infrared lamps. You can turn on one or both of them

for best heating effect.

2. Exhausting

Turn on/off ' ' button.

The heater can exhaust damp and steam in a quick and efficient way by turning on the ' '

button. No additional exhaust fan is necessary for the heater itself satisfies your need in

exhausting in bathroom.

3. Lighting

Turn on/off ' ' button.

Note: Assure all buttons under 'off' condition after use. Do not turn on/off the buttons

frequently when in use. Shut off power if in long vacancy

.

1. Cleaning

1) Shut off power before servicing or cleaning.

2) Wipe globes and fascia with care by a soft cloth soaked with neutral detergent. Ensure the

globes are cool to touch before handling.

3) Remove the fascia and lamps, remove the wire cover, unwire out plug, then take out 6

screws from clapboard. Remove clapboard for clean and maintenance.

Note: Electric parts are prohibited from touching water

.

4) Install all the parts in reverse after they become dry thoroughly.

2. Lamp Replacement

1) Check and tighten globes regularly

.

a) Position housing between joists and extend mounting brackets. Position brackets so that

bottom edge of housing will be flush with suspended ceiling. Mark the top of keyhole on all four

mounting brackets (Figure4).

b) Remove housing temporarily and pound nails partially into joists at all four marked locations

(Figure5).

c) Hang housing to nails. Pound nails tight.

Note: To ensure a noise-free mount, crimp the bracket channels tightly around mounting

brackets.

3. Fit the in-house end of the duct to the fan outlet of the housing (Figure6).

Keep the duct as straight as possible.

1. Replace the wire cover to the housing.

Figure 2

INSTALLATION

Figur e 3

1. Slide adjustable mounting brackets into bracket

channels on housing (Figure 3).

WIRING

1. Put one end of the interconnecting

wire through the opened knockout.

2. Make wire connections with the

terminal block as figure7.

Note: Make sure that connections are

used to hold wires firmly in place.

3. Connect the other end of

interconnecting wire with the switch

panel (Figure7).

Note:T ry to keep the redundant wire

away from the housing.

MAINTENANCE

3

4

5

6

mounting bracket

Fascia

Light lamp

housing

Heat lamp

Wire cover

knockout

K:Breaker H:Heat R:Light F:Exhaust

IN:Lighting lamp IR:Infrared lamp

:Heat protector

θ

M

IR

C

IN

θ

IR

IR

IR

L

L

120V 60Hz

N

GND

K

N

F

R

H

H

Exhaust

Light

Heat1

Heat2

#1

#2

#2

#1

Dear customers,

Thank you for selecting Aero Pure, which is surely to bring you satisfaction. Read all instructions

before using the heater.

1. Use this heater only as described in this manual. Any other use not recommended by the

manufacturer may cause fire, electric shock, or injury to persons. If you have questions, contact

the manufacture or local agent.

2. Make sure the power is off during the installation. Shut off power before servicing or cleaning.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with

all applicable codes and standards.

4. For the purpose of avoiding any dangerous gas leaking into your bathroom, the duct must not

be laid together with the vent-pipe of air-fueled water heater into the same flue.

5. To prevent a possible fire, do not block air intakes or exhaust in any manner.

6. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may

cause an electric shock or fire, or damage the heat.

7. A heater has hot and arcing or sparking parts inside. Do not use it in area where gasoline,

paint, or flammable liquids are used or stored.

8. The heater must not be installed at a place that suffers from severe water leakage.

9. Do not install closer than 10 inches to a vertical surface and 6 feet to the ground.

10. The heater must not be installed beneath a fixed socket.

11. When cutting into the wall, do not damage electrical wiring and other hidden utilities.

12.The unit has been tested to be in contact with insulation (Type IC).

13.The heater must be properly grounded.

CAUTION

14. For supply connections use No. 14 AWG or larger wires suitable for at least 90�(194�).

15. For overheat protection, exhausting automatically turns on when temperature above the

ceiling exceeds 90�(194�).

16. The lamps are hot when in use. It is absolutely prohibited to touch the infrared lamps with

any part of your body when in use.

17. Shut off power urgently when any abnormalities occur in operation. Then call your local

licensed electrician for inspection or necessary service work.

18. Children, elders and / or handicapped should use this product under family guidance.

19. Do not use out doors.

20.To reduce risk of fire, use only type RF lamps 270 watts maximun. Replace bulb with 60

watts type A bulb only. It may affect operation (even cause danger) when use lamps other than

the designated one.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and

vapors.

2. This product is designed for installation in flat ceilings only. Do not mount it on a sloping

ceiling or a vertical wall.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray,

construction dust, etc. off the unit.

4. It is highly recommended to make preparation for heater installation when you retrofit your

bathroom.

5. Please read specification label on product for further information and requirements.

1. Cutting a vent (Figure1)

Locate a vent position (above the ceiling) on the wall, and then cut a 4 1/8 inches diameter hole

at the very position.

PREPARATION FOR INSTALLATION

INSTALLATION

A716

1

2

Aero Pure Fans LLC
3270 Associate Drive
Suite B
North Charleston, SC29418
Office: 843 377 8642
Fax: 843 377 8643

User's Manual

BATHROOM HEATER

SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS
BEFORE USING THE HEATER.

WARNING!

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO

PERSONS, OBSERVE THE FOLLOWING:

WARRANTY

2) Shut off power before replacement.

3) Use a 120V~, maximum 60W type A bulb only for lighting.

4) Use our designed 120V~,270W infrared lamps.

The product is warranted against parts failure for a period of 4 years. Labor costs extra. Please

contact your local agencies for warranty services.

This warranty does not cover damage or loss caused by:

a. Light lamp.

b. Any consequential losses arising from incorrect installation or operation or maintenance of

this product.

c. Any consequential losses arising from incorrect wiring of this product.

d. Any consequential losses arising from repairing of any part of this product by unauthorized

persons.

Model

Rated Voltage

Rated Frequency

Rated Power

A716
120V
60Hz

1160W

Main Technical Parameters

1 Piece

4 Pieces

1 Piece
1 Piece
1 Piece

1 Set

Operation Unit

Infrared Heat Lamp

Light Lamp

User's Manual

Ventiduct

Mounting Bracket

List of Accessories

We keep the right to revise this manual without any prior notice.

ceiling

joist

ceiling

outside

wall

ventiduct

Φ4 1/8 inches

cutting Φ4 1/8 inches hole

Figure 1

Figure5

mounting bracket

Figure4

Figure6

ventiduct

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Aero Pure Exhaust Fans Models