Page 4 - Introduction; The main features of the reader are listed below:
Rev 09 --------------------------------------------------------------------------------4/27-------------------------------------------------------------------------------- 1 Introduction This document describes the RFID-reading device ARE DT1 LF and the set-up procedure. The main features of the rea...
Page 5 - Startup and testing the reader; Connect the reader with the USB interface from your notebook or pc; AEG ID instruction set
Rev 09 --------------------------------------------------------------------------------5/27-------------------------------------------------------------------------------- 2 Startup and testing the reader • Connect the reader with the USB interface from your notebook or pc • The reader is supplied v...
Page 6 - Entering instructions; The protocol format is as follows; Output format
Rev 09 --------------------------------------------------------------------------------6/27-------------------------------------------------------------------------------- 3.1.1 Entering instructions The protocol format is as follows Command <SP> parameter <CR> The space character <SP...
Page 7 - Output at parameter query; MD; Blank instuction; ERROR CODE
Rev 09 --------------------------------------------------------------------------------7/27-------------------------------------------------------------------------------- 3.1.2.3 Output at parameter query Parameter settings can be queried by sending the command without adding a parameter value. Exa...
Page 8 - Upper and lower case; The instruction set isn’t case-sensitiv.; Linefeed
Rev 09 --------------------------------------------------------------------------------8/27-------------------------------------------------------------------------------- 3.1.5 Upper and lower case The instruction set isn’t case-sensitiv. 3.1.6 Linefeed The reader does never send a linefeed. If you...
Page 9 - BD; EC – Echo; The EC command allows to change the echo function.; EC; Echo off; PARAMETER
Rev 09 --------------------------------------------------------------------------------9/27-------------------------------------------------------------------------------- 3.2 Instructions for the hardware settings 3.2.1 BD – baudrate The command BD enables the change of the baud rate. The settings ...
Page 10 - LED – LED control; With the command LED you can control the LED ring of the ARE DT1.; LED; off; RST – reset; RST
Rev 09 --------------------------------------------------------------------------------10/27-------------------------------------------------------------------------------- 3.2.3 LED – LED control With the command LED you can control the LED ring of the ARE DT1. Input format: LED <SP> paramete...
Page 11 - HF – Antenna field; With the command HF, the antenna field can be set or reset manually.; HF; Switch off antenna field (this stops automatic mode)
Rev 09 --------------------------------------------------------------------------------11/27-------------------------------------------------------------------------------- 3.2.5 HF – Antenna field With the command HF, the antenna field can be set or reset manually. Input format: HF <SP> param...
Page 12 - HID – human interface device/keyboard; HID
Rev 09 --------------------------------------------------------------------------------12/27-------------------------------------------------------------------------------- 3.2.6 HID – human interface device/keyboard The command switches the interface ether to HID or RS232 emulation. Input format: H...
Page 13 - KL – keyboard language; KL; VER – version; VER
Rev 09 --------------------------------------------------------------------------------13/27-------------------------------------------------------------------------------- 3.2.7 KL – keyboard language With the command KL you can configure the language of the keyboard in HID mode. Input format: KL &...
Page 14 - only the first
Rev 09 --------------------------------------------------------------------------------14/27-------------------------------------------------------------------------------- 3.3 Instructions for reading settings 3.3.1 CID – suppression of ID Codes In the MD0 mode with CID=1 only the first of in succe...
Page 15 - CN – suppression of No Reads; CN
Rev 09 --------------------------------------------------------------------------------15/27-------------------------------------------------------------------------------- • after a warm start (command line RST <CR>) • after entering the command line CID <SP> 1 <CR> This causes th...
Page 16 - NID – Failure Protection; NID; INIT – initialization; INIT
Rev 09 --------------------------------------------------------------------------------16/27-------------------------------------------------------------------------------- 3.3.3 NID – Failure Protection NID specifies the number of identical transponder numbers, which have to appear for the result “...
Page 17 - LAA – LED automatic activity; LAA; controlled by reader; TSC – time show code; TSC; TSC is not active
Rev 09 --------------------------------------------------------------------------------17/27-------------------------------------------------------------------------------- 3.3.5 LAA – LED automatic activity The leds can be controlled by the reader or over the interface. You can set it up with the c...
Page 18 - TOR – maximum reading time; The time constant TB (time base) has always the default value 100ms.; TOR; VSAVE – variables save; VSAVE; just available in the ISO 14443A standard; limits the reading process duration of exactly one reading cycle
Rev 09 --------------------------------------------------------------------------------18/27-------------------------------------------------------------------------------- 3.3.7 TOR – maximum reading time TOR is the timeout time for the reader. TOR is used in operation mode 2 as maximum gating time...
Page 19 - VS – variables show; VS; SA – algorithm selection; SA
Rev 09 --------------------------------------------------------------------------------19/27-------------------------------------------------------------------------------- 3.3.9 VS – variables show With the command VS the reader shows the settings of the following parameters: BD, CID, CN, EC, MD, N...
Page 20 - GT; MD – mode of operation; constant reading mode; Basic data exchange process
Rev 09 --------------------------------------------------------------------------------20/27-------------------------------------------------------------------------------- 3.4 General reading instructions 3.4.1 GT – get tag The instruction GT executes one reading and sends back the transponder code...
Page 21 - RD – read page; Wait for the answer; read block 20; RD; read all blocks from 16 to 33
Rev 09 --------------------------------------------------------------------------------21/27-------------------------------------------------------------------------------- 3.4.4 RD – read page • Start the reader with the command RD plus parameters (plus <CR>). You can read out just one block ...
Page 22 - WD – write page
Rev 09 --------------------------------------------------------------------------------22/27-------------------------------------------------------------------------------- 3.4.5 WD – write page The memory of the transponder is organised in blocks, containing 32 bits. The data’s of every single bloc...
Page 23 - Operating modes of the reader; MD 0 - continuous mode; MD 2 - triggered by an software command; Figure 9: Software triggered reading operation
Rev 09 --------------------------------------------------------------------------------23/27-------------------------------------------------------------------------------- 4 Operating modes of the reader In the AEG instruction set there are two operational modes defined: • MD 0 - continuous mode • ...
Page 24 - Figure 10: Software triggered reading operation with TOR>0; Please note; MD 0 - continuous reading; Figure 11: continuous operation
Rev 09 --------------------------------------------------------------------------------24/27-------------------------------------------------------------------------------- Figure 10: Software triggered reading operation with TOR>0 Please note : The TOR parameter is only active, if the GT-Command...
Page 25 - Instructions
Rev 09 --------------------------------------------------------------------------------25/27-------------------------------------------------------------------------------- 5 Instructions To avoid any reduction of the reading distance of the reader, the reader must not be brought next to a metal sur...
Page 26 - FCC Information; Federal Communications Commissions (FCC) Statement; Reorient or relocate the receiving antenna.
Rev 09 --------------------------------------------------------------------------------26/27-------------------------------------------------------------------------------- 6 FCC Information Federal Communications Commissions (FCC) Statement 15.21 You are cautioned that changes or modifications not ...