FLUXPOWER

HPS

400-500-600-800 KVA

3-phase UPS

High power solution for large,

mission-critical systems

Flexible and smart

The innovation and design of the Fluxpower HPS high

power UPS has resulted in the unit being the most

technologically advanced in its class.

It delivers an incredible combination of low input current

distortion, unity input power factor and high overall effi ciency.

These advances in design offer numerous benefi ts, including

lower running costs and substantially increased reliability.

Low THDi and power factor performance

The Fluxpower HPS model UPS uses a completely new IGBT input

rectifi er design, encompassing an advanced PFC (Power Factor

Control) which is capable of keeping input current THDi (Total

Harmonic Distortion) at a level of less than 3 % and input power

factor within 1 % of unity, even when only small loads are applied.

The key benefi ts are that the UPS is compatible with the

upstream source, the mains or any kind of generator and the

transfer of power between source and load is more effi cient.

This results in a saving in terms of scale of sources, cables

and protective devices.

High effi ciency reduces overall cost

of ownership

Fluxpower HPS has a new Wise ECO function which enables a

total operating effi ciency of between 95 % and 98 %. This mode,

referred to as “Intelligent ECO mode”, signifi cantly reduces

the utility costs associated with operating a device of this type.

Moreover, this increase in effi ciency results in the production

of less waste heat, minimizing cooling / air-conditioning costs.

This represents a double saving to the energy conscious user.

The Wise ECO function uses continual monitoring techniques to

review the input characteristics of the supply. This means that if the

supply line drops or fl uctuates outside of acceptable conditions the

UPS uses the internal inverter to support the load. This is achieved

through a fast, fully static transition from VFD to VFI mode.