Ademco VISTA-100 - Installation Manual

Ademco VISTA-100

Ademco VISTA-100 Security System – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
146 Page 146
147 Page 147
148 Page 148
149 Page 149
150 Page 150
151 Page 151
152 Page 152
153 Page 153
154 Page 154
155 Page 155
156 Page 156
157 Page 157
158 Page 158
159 Page 159
160 Page 160
161 Page 161
162 Page 162
163 Page 163
164 Page 164
165 Page 165
166 Page 166
167 Page 167
168 Page 168
169 Page 169
170 Page 170
171 Page 171
172 Page 172
173 Page 173
174 Page 174
175 Page 175
176 Page 176
177 Page 177
178 Page 178
179 Page 179
180 Page 180
181 Page 181
182 Page 182
183 Page 183
184 Page 184
185 Page 185
186 Page 186
187 Page 187
188 Page 188
189 Page 189
190 Page 190
191 Page 191
192 Page 192
193 Page 193
194 Page 194
195 Page 195
196 Page 196
197 Page 197
198 Page 198
199 Page 199
200 Page 200
201 Page 201
202 Page 202
203 Page 203
204 Page 204
205 Page 205
206 Page 206
207 Page 207
208 Page 208
209 Page 209
210 Page 210
211 Page 211
212 Page 212
213 Page 213
214 Page 214
215 Page 215
216 Page 216
217 Page 217
218 Page 218
219 Page 219
220 Page 220
221 Page 221
222 Page 222
223 Page 223
224 Page 224
225 Page 225
226 Page 226
227 Page 227
228 Page 228
229 Page 229
230 Page 230
231 Page 231
232 Page 232
233 Page 233
234 Page 234
Page: / 234

Table of Contents:

  • Page 2 – ii; Recommendations for Proper Protection; Recommendations For Smoke And Heat Detectors; UL
  • Page 3 – iii
  • Page 4 – iv; Table of Contents
  • Page 8 – THE LIMITATIONS OF THIS ALARM SYSTEM
  • Page 9 – ix; List of Figures
  • Page 10 – How To Use This Manual; A general description of the entire system
  • Page 11 – xi; Conventions Used in This Manual; INSTALLER CODE
  • Page 12 – VISTA-100 Installation Instructions; S E C T I O N 1; General Description; In This Section; General Overview; The major system features are outlined below.; Basic Hardwired Zones
  • Page 13 – Section 1 - General Description; Supervisory Zones
  • Page 14 – User Codes
  • Page 15 – Auxiliary Relay; Access Control; Optional 24-Volt Power Supply
  • Page 18 – S E C T I O N 2; Planning a Partitioned System; Theory of Partitioning
  • Page 19 – Common Lobby Logic
  • Page 20 – Section 2 - Planning a Partitioned System; Affects Lobby; MAIN ENTRANCE; COMMON LOBBY; Office 1
  • Page 21 – Arming/Disarming Remotely
  • Page 22 – Master Keypad Setup and Operation
  • Page 24 – S E C T I O N 3; False Alarm Reduction Features; General Information
  • Page 25 – Recent Close Report; Cross Zoning; • Both must protect the same area; Conditions That Affect Cross-Zone Operation
  • Page 26 – Call Waiting Defeat Logic
  • Page 28 – S E C T I O N 4; Installing The Control; Insert the key into the lock. Position the lock
  • Page 29 – Grade A Mercantile Premises Listing; indicated in the diagram below.; Figure 4-2. Cabinet Attack Resistance Considerations; Grade A Mercantile Safe and Vault Listing
  • Page 30 – Section 4 - Installing The Control; Installing the Control's Circuit Board; with the accompanying screws.; Connecting the AC Transformer and Battery
  • Page 31 – Panel Earth Ground Connections; To ground the panel, take the following steps:
  • Page 32 – S E C T I O N 5; Installing The Keypads; You may use the following keypads with the VISTA-100:; Wiring to the Keypads; To wire the keypads, take the following steps:; Wire Run Length Table
  • Page 33 – Using a Supplementary Power Supply to Power Additional Keypads
  • Page 34 – Mounting the Keypads
  • Page 35 – Programming Remote Keypads
  • Page 36 – S E C T I O N 6; supervision is required for fire and UL Burglary installations.); Wiring Burglary and Panic Devices to Zones 1-8; connected across the loop wires at the last device.
  • Page 37 – Wiring 2-Wire Smoke Detectors to Zones 1 and 2
  • Page 38 – Compatible 2-Wire Smoke Detectors; DETECTOR TYPE; Wiring 4-Wire Smoke Detectors to Zones 1-8
  • Page 39 – Compatible 4-Wire Smoke Detectors; Photoelectric, direct wire; Fire Alarm Verification for Smoke Detectors
  • Page 40 – Wiring 2-Wire Latching Glassbreak Detectors to Zone 8; Figure 6-3. Wiring Latching Glassbreak Detectors to Zone 8; Compatible Glassbreak Detectors; Use detectors that meet the following ratings:
  • Page 41 – Programming and Checkout of Hardwired Zones
  • Page 42 – S E C T I O N 7; -Wire Polling Loop Expansion; Refer to the list of compatible devices at the end of this section.; Common Characteristics of Polling Loop Zones; Polling loop zones have the following characteristics:; Wiring/Addressing RPM Devices
  • Page 43 – Maximum Polling Loop Wire Runs
  • Page 44 – Section 7 - 2-Wire Polling Loop Expansion; DO NOT use the 4197 Polling Loop Extender Module with the VISTA-100.
  • Page 46 – Polling Loop Supervision
  • Page 47 – Models 7500 and 9500 Glassbreak Detectors are not UL Listed.
  • Page 48 – S E C T I O N 8; Wireless Zone Expansion; Individually assignable to one of 8 partitions; Wireless Systems Available; Receiver; up to 4
  • Page 49 – up to 8; RF System Operation and Supervision; redundant protection.; RF System Installation Advisories
  • Page 51 – Installing the 5800TM Module; For additional information, refer to the 5800TM’s instructions.; Programming the RF Receiver
  • Page 52 – Section 8 - Wireless Zone Expansion; 700 Series Transmitter Setup; Transmitter Supervision; OFF to clear its memory of the “Low Battery” signal.; Installing the Transmitters; To install RF transmitters, take the following steps:; Wireless Zone Assignments for 5700 Series Transmitters
  • Page 53 – Zone Type
  • Page 54 – Compatible 5700 Series Transmitters (cont’d); 800 Series Transmitter Setup
  • Page 55 – UR or RF
  • Page 56 – Compatible 5800 Series Transmitters (cont’d)
  • Page 57 – Programming and Checkout of Wireless Zones
  • Page 58 – S E C T I O N 9; Relay Outputs; Relay Basics; To wire the 4204 or 4204CF Relay Module, take the following steps:
  • Page 60 – Section 9-Relay Outputs; Programming Relay Modules and Output Devices
  • Page 62 – S E C T I O N 1 0; The 4285/4286 VIP Module offers the following features:; Mounting the VIP Module
  • Page 63 – Wiring the VIP Module; Terminal Block Connections
  • Page 64 – Programming the VIP Module
  • Page 66 – S E C T I O N 1 1
  • Page 67 – Audio Alarm Verification Module Connections; address, temporarily apply power to the system.
  • Page 68 – Section 11 – Audio Alarm Verification (AAV) Unit; Figure 11-1. Audio Alarm Verification Module Connections
  • Page 70 – S E C T I O N 1 2; J2 Trigger Outputs; • Remote keypad sounder
  • Page 71 – Remote Keypad Sounder Operation and Wiring; Figure 12-2. Remote Keypad Sounder Wiring; Remote Keyswitch Operation and Wiring
  • Page 73 – Keyswitch Operation With Alarms Present:
  • Page 74 – Section 12 – J2 Trigger Outputs; Auxiliary Alarm Signaling Equipment
  • Page 75 – Figure 12-5a. Connections to 7720 Long Range Radio
  • Page 76 – Figure 12-5c. Connections to 7920SE Long Range Radio
  • Page 77 – Event Log Printer Connections; If earth ground fault sensing is enabled:; Direct Wire Downloading
  • Page 79 – S E C T I O N 1 3; External Sounders; Bell Circuit Supervision; To supervise bell circuits, take the following steps:; each bell output you want supervised.
  • Page 80 – Programming the Bell Outputs; Model
  • Page 81 – Section 13 - External Sounders; Strobe; Figure 13-1. External Sounder Connections
  • Page 82 – S E C T I O N 1 4; Relay Functions; These functions are described below.; Figure 14-1. Auxiliary Relay Used as Unsupervised Bell Output
  • Page 84 – Section 14- Auxiliary Relay
  • Page 85 – S E C T I O N 1 5; Dialer Outputs; Dialer Outputs Available; Telephone Line Supervision; DO NOT connect both outputs to the same telephone company line.
  • Page 86 – Dialer Operation; The VISTA-100 will transmit reports in the following order:
  • Page 87 – Section 15- Dialer Outputs
  • Page 88 – S E C T I O N 1 6; Event Log Options; To enable event log printing, take the following steps:
  • Page 89 – Figure 16-1. Event Log Printer Connections; cannot be lengthened to mount the module in a remote location.; Programming Event Log Options; To program event log options, take the following steps:
  • Page 90 – Section 16- Event Log Options; Event Logging Procedures
  • Page 91 – Display shows all test events.; SCREEN DEFINITIONS; RECENT
  • Page 93 – S E C T I O N 1 7; Final Power-Up Procedure; Connecting the AC Transformer; Remove the front cover of the enclosure.
  • Page 94 – Connecting the Panel to Earth Ground; to determine the total current drawn from the polling loop.
  • Page 95 – Section 17 – Final Power-Up; Connecting the Backup Battery to the Control; Figure 17-1. Connecting the Backup Batteries to the Control
  • Page 96 – Total Control Panel Load Worksheets; Enter devices used on; Enter devices connected
  • Page 98 – BATTERY SELECTION TABLE
  • Page 100 – S E C T I O N 1 8; The Mechanics Of Programming; then either make the required entry in the new field, or press; System and Communication Defaults; 7) enable keypad addresses 00-03 only. You must use a keypad
  • Page 101 – Entering Data Field Programming Mode
  • Page 102 – Section 18 - The Mechanics of Programming; SUMMARY OF DATA FIELD PROGRAMMING COMMANDS; Programming System-Wide Data Fields; Press; Programming Partition-Specific Data Fields; The system will prompt you for the partition number.
  • Page 103 – #93 Menu Mode Programming; #93 Menu Mode Key Commands
  • Page 104 – S E C T I O N 1 9; Zone Number Designations; Zone; Traditional hardwired zones; Zone Type Definitions; Type 00: Zone Not Used
  • Page 105 – Type 03: Perimeter Burglary
  • Page 106 – Section 19 - Zone Type Definitions; Type 17: Fire Waterflow
  • Page 108 – S E C T I O N 2 0; Zone Index/Zone Type Defaults; Zone Index; ZONE NUMBER RANGE
  • Page 109 – Zone Type Defaults
  • Page 110 – S E C T I O N 2 1; Data Field Descriptions; *08 TEMPORAL SIREN PULSE; If you program either bell for pulsing (program field 3
  • Page 111 – *15 KEYSWITCH ASSIGNMENT
  • Page 112 – Section 21 - Data Field Descriptions; You must set this field to 1 for UL installations.; Note that if the previous state was
  • Page 113 – *30 TOUCHTONE OR ROTARY DIAL; This field is applicable only if the user will use downloading.
  • Page 114 – *36 DOWNLOAD ID NUMBER; 3 to disable the download callback option.; Set this field to 0 for Commercial Fire and UL installations.
  • Page 115 – *44 RING DETECTION COUNT
  • Page 116 – *79 ZONE TYPE RESTORES FOR ZONE TYPES 1-8
  • Page 117 – Set this field to 0 for UL installations.; . This account number can be the; *20 EXIT ERROR LOGIC
  • Page 118 – You must set this field to 000,000 for UL Burglary Installations.
  • Page 119 – *42 CALL WAITING DEFEAT
  • Page 120 – *53 DISABLE DOWNLOAD CALLBACK; *73 PRINTER BAUD RATE
  • Page 121 – *00 NUMBER OF PARTITIONS; You must set fields 2*05 through 2*08 to 0 for UL installations.
  • Page 122 – *11 ALLOW DISARM OUTSIDE WINDOW IF ALARM OCCURS; Used this field only if field 2; *19 USE PARTITION DESCRIPTORS
  • Page 123 – Enter 1 to enable zone 6 as a tamper zone.; This option allows the delay time programmed in field 3
  • Page 124 – Enter 1 to enable each dialer that exists in the system.
  • Page 125 – *61 AUX RELAY FUNCTION
  • Page 126 – S E C T I O N 2 2; polling loop devices (all other zone characteristics must be
  • Page 128 – Zone Programming; 7 will not delete the tool’s serial
  • Page 132 – Enrolling Serial Numbers in Sequential Mode
  • Page 133 – 7 will not delete the tool’s serial number.); A loop number programmed
  • Page 135 – Report Code Programming; ALARM CODES; Zone Alarm Reports
  • Page 137 – System Group 1 Codes
  • Page 138 – Programming Alpha Descriptors
  • Page 139 – Zone Descriptors
  • Page 140 – Custom Words
  • Page 141 – Partition Descriptors
  • Page 142 – Store the new display message in memory by pressing 8.; The system will ask for the next partition number.; Enter 0 to quit or 1-8 to enter a new partition number.
  • Page 143 – ALPHA DESCRIPTOR VOCABULARY
  • Page 144 – Device Programming
  • Page 145 – Relay Programming
  • Page 147 – Programming Relay Output Devices
  • Page 148 – Type/System Operation table above. Press; specific group number. Press
  • Page 149 – Zone List Programming
  • Page 150 – Relay Voice Descriptors
  • Page 151 – Relay Voice Descriptors and Custom Word Substitutes Vocabulary; Custom Word Substitutes for VIP Module Annunciation; To enter custom word substitutes, take the following steps:; Enter 1 at this prompt.
  • Page 152 – to accept the entry.; RF Serial Number Clear Mode; The RF Serial Number Clear mode will; not delete polling loop serial numbers.; To clear all RF wireless serial numbers, take the following steps:
  • Page 153 – S E C T I O N 2 3; Scheduling Options; Auto-disarming is not for use in UL installations.
  • Page 155 – Section 23 - Scheduling Options; Time Windows Definitions; Window
  • Page 157 – Open/Close Definitions; Daily Schedule; Example of Open/Close Exception Reporting & Scheduling
  • Page 158 – Programming with #80 Scheduling Menu Mode; Steps to Programming Scheduling Options; Basic Scheduling Menu Structure
  • Page 160 – Time Windows Definitions Worksheet; Programming Time Windows; You cannot enter Scheduling Mode if any partition is armed.
  • Page 161 – Daily Open/Close Worksheet
  • Page 163 – Holiday Definitions & Schedule Worksheet; Programming Holiday Schedules
  • Page 164 – Time-Driven Event Worksheet; To fill out the worksheet, take the following steps:
  • Page 165 – Relay commands
  • Page 166 – Action Code; Time-Driven Event Programming
  • Page 168 – : Trigger at both the start and the end of the window.; Limitation of Access by Time Worksheet
  • Page 169 – #81 Temporary Schedule Menu Mode
  • Page 171 – Programming Temporary Schedules
  • Page 172 – #83 User Scheduling Menu Mode
  • Page 173 – Enter 0 to put the schedule in effect for one week only.
  • Page 174 – S E C T I O N 24; System Communication; A Successful Transmission
  • Page 176 – Section 24 - System Communications; ADEMCO High Speed Reporting events by channel:; Channels 1 through 8 could have one of the following conditions:
  • Page 177 – Loading Communication Defaults; TABLE OF DEFAULT PROGRAMMING COMMANDS; • Assigns the following report codes:
  • Page 178 – TABLE OF CONTACT ID EVENT CODES
  • Page 180 – COMMUNICATION DEFAULTS FOR ZONES
  • Page 181 – COMMUNICATION DEFAULTS FOR ZONES (cont’d)
  • Page 182 – TROUBLE
  • Page 183 – BYPASS
  • Page 184 – S E C T I O N 25; Downloading Primer; (Remote Downloading is not a UL Listed feature); OR; Getting On-Line with a Control Panel
  • Page 185 – On-Line Control Functions
  • Page 186 – Section 25 - Downloading Primer; Access Security; the pre-programmed number only if the security codes match.; Connecting a 4100SM Module for Direct-Wire Downloading
  • Page 188 – S E C T I O N 26; Setting The Real-Time Clock
  • Page 190 – S E C T I O N 27; User Access Codes; To; You must program User #002 for the Quick Arm feature to function.; User Codes and Levels of Authority; Level Title
  • Page 191 – Level 1: Master Codes
  • Page 192 – Level 6: Duress Codes; that to which he is assigned.
  • Page 193 – Section 27 - User Access Codes; Multiple Partition Access Examples; To ADD a Master, Manager, or Operator Code
  • Page 195 – ) indicates the partition; To CHANGE a Master, Manager, or Operator Code; To exit User Edit Mode, take ONE of the following steps:
  • Page 196 – S E C T I O N 28; Keypad Functions
  • Page 197 – Global Arming
  • Page 198 – Section 28 - Keypad Functions; Viewing Capabilities of a User
  • Page 199 – Viewing Zone Descriptors; The panic functions are identified by the system as follows:
  • Page 200 – Desired function; ENTER USER CODE
  • Page 201 – On the keypad, press
  • Page 202 – S E C T I O N 29; Testing The System; If the following is displayed,; press
  • Page 203 – Checkout Procedure for Polling Loop Zones; system should display:; press the
  • Page 204 – The 4278 auxiliary sensor loop cannot be used.; Checkout Procedure for Wireless Zones; Transmitter ID Sniffer Mode; wireless units programmed into the system.
  • Page 205 – Battery Test
  • Page 207 – Armed Burglary System Test; To conduct an Armed Burglary System Test, take the following steps:
  • Page 208 – Section 29 - Testing The System; Trouble Conditions; Supervisory Messages; A polling loop zone is not detected by the control panel.; Other System Messages; Indicates that the control is on-line with a remote computer.; Fire System Off-Normal Report
  • Page 209 – Power Failure; Turning the System Over to the User
  • Page 210 – Contacting Technical Support; along with any documentation that came with the product.
  • Page 212 – A P P E N D I X A; Regulatory Agency Statements; UL Installation Requirements; All partitions must be owned and managed by the same person(s).; UL864/NFPA Local Fire
  • Page 213 – UL365 Police Station Connected Burglar Alarm; Follow the instructions below for UL609 local installations.; For Grade AA Service:; You must use a 7920SE Long Range Radio.
  • Page 214 – Appendix A - Regulatory Agency Statements; California State Fire Marshal (CSFM) Requirements
  • Page 218 – A P P E N D I X B; DIP Switch Tables
  • Page 220 – Appendix B - DIP Switch Tables; DIP SWITCH TABLES FOR POLLING LOOP DEVICES
  • Page 221 – DIP SWITCH TABLES FOR 5700 RF SYSTEM WIRELESS DEVICES
  • Page 222 – A P P E N D I X C; Summary of System Commands
  • Page 223 – Scheduling
  • Page 224 – A P P E N D I X D; Specifications; 140DLM BACKUP DIALER MODULE
  • Page 225 – DIGITAL COMMUNICATOR
  • Page 226 – Index
  • Page 232 – ADEMCO LIMITED WARRANTY; Notes
Loading the manual
Page 1

N6019-2V1 1/98

VISTA-100

COMMERCIAL FIRE AND BURGLARY

PARTITIONED SECURITY SYSTEM

with SCHEDULING

INSTALLATION INSTRUCTIONS

and

PROGRAMMING GUIDE

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Ademco
Model
VISTA-100
Document type
Installation Manual
Category
Security System
Language(s)
English
Pages
234
Format
PDF

Summary

Page 2 - ii; Recommendations for Proper Protection; Recommendations For Smoke And Heat Detectors; UL

ii Recommendations for Proper Protection The Following Recommendations For The Location Of Fire And Burglary Detection Devices Help ProvideProper Coverage For The Protected Premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subs...

Page 3 - iii

iii In addition, we recommend that radio backup be used in a security system so that alarm signals canstill be sent to the alarm monitoring station in the event that the telephone lines are out of order (alarmsignals are normally sent over the phone lines, if connected to an alarm monitoring station...

Page 4 - iv; Table of Contents

iv Table of Contents • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • RECOMMENDATIONS FOR PROPER PROTECTION .................................................................. ii HOW TO USE THIS MANUAL .......................................................

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.