Page 3 - Contents
English 1 Contents Dear Customers .......................................................................2 Preliminary Remarks .................................................................2 Precautions ..............................................................................2 Parts Identifi...
Page 4 - Dear Customers; Preliminary Remarks
English 2 Dear Customers Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this ...
Page 5 - Contraindications
English 3 Measurements may be distorted if the device is used close to televisions, microwave ovens, cellular telephones, X-ray or other devices with strong electrical fields. Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the ap...
Page 6 - Parts Identification; Part of Display
English 4 Parts Identification Part of Display Pressure Bar Indicator MEMORY Systolic Pressure Diastolic Pressure Pulse Rate Battery Indicator I.H.B. Indicator (Irregular heartbeat indicator) Heart Mark Battery Cover 1.5V Batteries (LR6, R6P or AA) Battery Compartment Display Air Connector Plug Air ...
Page 8 - Using the Monitor; Installing / Changing the Batteries; Connecting the Air Hose
English 6 Symbols Function / Meaning Recommended Action Date of manufacture Class II device WEEE label Refer to instruction manual/booklet SN Serial number Polarity of DC jack Using the Monitor Installing / Changing the Batteries 1. Slide the battery cover up to open it. 2. Remove the used batteries...
Page 9 - Wireless Function; Bluetooth Transmission
English 7 Using the Monitor Wireless Function CAUTION In the unlikely event that this monitor causes radio wave interference in a different wireless station, change the location where this monitor is used or stop use immediately. Be sure to use in a location where visibility between the two devices ...
Page 12 - Selecting the Correct Cuff Size
English 10 Using the Monitor Selecting the Correct Cuff Size Using the correct cuff size is important for an accurate reading. If the cuff is not the proper size, the reading may yield an incorrect blood pressure value. The arm size is printed on each cuff. The index and proper fit range, on the cuf...
Page 13 - Applying the Arm Cuff
English 11 Do not roll up shirtsleeve tightly 1 to 2 cm Air hose Cuff Index and Proper fit range Artery position mark Secure the fabric fastener firmly Using the Monitor Applying the Arm Cuff 1. Wrap the cuff around the upper arm, about 1-2 cm above the inside of the elbow, as shown. Place the cuff ...
Page 14 - Measurements; Normal Measurement
English 12 Measurements Model UA-767 BT-Ci is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically. If your systolic pressure is expected to exceed 230 mmHg or you use the optional small cuff, read "Measurement with the desired systolic pressure" on...
Page 15 - Measurement with the Desired Systolic Pressure
English 13 Measurements Measurement with the Desired Systolic Pressure If your systolic pressure is expected to exceed 230 mmHg or you use the optional small cuff, use this procedure. 1. Place the cuff on the arm (preferably the left arm). 2. Press and hold the START button until a number about 30 t...
Page 16 - What is an Irregular Heartbeat
English 14 What is an Irregular Heartbeat Model UA-767 BT-Ci blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pr...
Page 17 - About Blood Pressure; What is Blood Pressure?
English 15 Reference Material: Journal of Hypertension 1999, Vol 17 No.2 mmHg 110105100 95908580 Optimal 120 130 140 150 160 170 180 Systolic blood pressure mmHg Normal High-normal Grade 1 hypertension (mild) Grade 2 hypertension (moderate) Grade 3 hypertension (severe) Dia stolic bl ood pre ssure A...
Page 18 - Troubleshooting
English 16 Typical fluctuation within a day(Measured every five minutes) PM AM Time Bloo d pre ssure Systolic Diastolic Sleep described in this manual to get to know your normal blood pressure. Regular readings give a more comprehensive blood pressure history. Be sure to note date and time when reco...