3M 1210 - Manual
3M 1210 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – The 3M Electronic Pipettor 5mL includes:
- Page 3 – Charging the Pipettor Battery; Instructions For Use; Connecting the AC Adapter
- Page 4 – Pipettor Programming; The Program Menu
- Page 8 – mL Pipetting
- Page 9 – Open Dilution Programming; mL Pipetting
- Page 10 – Speed Selection
- Page 11 – Liquid in Tip Cone; Troubleshooting
- Page 12 – Filter Replacement; Care and Maintenance
- Page 13 – Table 1; Calibration Check Chart; Battery Replacement
- Page 14 – Accuracy and Precision
- Page 15 – Limited Warranty; Limitation of Remedies:
Description
2
Each unit includes the following items:
• 1 Electronic Pipettor
• 1 Charging Stand
• 1 AC Adapter
• 1 Test Performance Certificate
• 1 Instruction Manual
• 1 Quick Reference Card
• Replacement Tip Cone Filters (50/bag)
Make sure that all items are included
and that no damage has occurred during
shipment. Also check that the AC adapter matches your electrical requirements.
Pipettor Controls
These controls are often referred to in this manual.
Speed Key Changes aspiration and dispense speeds
Mode Key Shifts to next mode
Up Key Increases open volume or speed
Down Key Decreases open volume or speed
Recall Key Flips back to last mode entered
Enter Key Selects mode, speed or volume changes
Start Button Triggers all mechanical operations
Tip Ejector Lever Squeezed to remove pipette tip
ON-OFF SWITCH
The On-Off Switch is located at the
back of the pipettor. Slide to the left
position to switch "ON" and to the
right to switch "OFF".
AC adapter
ON
OFF
keypad
display
start button
tip ejector
lever
tip ejector
collar
tip cone
charging stand pipettor
filter
Electronic Pipettor - 5mL
Pipette Electronique - 5mL
Elektronische Pipette - 5mL
Pipetta Elettronica - 5mL
Pipeteador electrónico - 5mL
6483
5mL
FOD# 1210
Page 1 of 15 - June 2001
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Precautions 4 • Always follow Good Laboratory Practices. • Avoid contamination of the tip cone. Do not rest the pipettor on its side. Always place the pipettor in the charging stand when not in use. • Ensure consistent technique to maintain precise results. • Never strike the pipettor tip cone again...
Instructions For Use 6 1. Connect the AC adapter into the connector jack at the rear of the charging stand's base. 2. Plug the AC adapter into an AC electrical outlet. 3. The green light at the top of the charging stand indicates that the stand is in operation. The light will always be on when plugg...
Power “ON” Display and Startup The display of a switched “ON” pipettor indicates that programming has been resetto default settings. 1. Switch the unit “ON”. Display: 2. Press the Start Button twice. The display shows that the unit is ready for the default 1:5 dilution (Mode d1, 5mL) or for program ...