Page 2 - CONTENTS; Programmable DC; Chapter 3 Installation of PowerMS Software
3600 Series Programmable Power Supply VERSION 2.0 2004.6 26 3600 SERIES USER MANUAL Safety Guide...............................................1 Attention......................................................2 Chapter 1 General Introduction ...................4 1.1 General Introduction.................
Page 3 - the danger levels as follows:; Danger; will take place; Warning; available safety practices and standards.; Note; tions properly and reliably.
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 1 SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with a triangle “WAR...
Page 5 - 600 Series Programmable Power Supply; Please be sure that the power supply is grounded.
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 3 3. Connect the power cable to the AC in the power supply and the 3 connector plug. Please be sure that the power supply is grounded. 4. Press the switch on the front panel to switch on the instrument and you can start...
Page 6 - Chapter 1 General Introduction
3600 Series Programmable Power Supply VERSION 2.0 2004.6 4 3600 SERIES USER MANUAL Model 3644A 3645A 3646A Number of outputs 1 1 1 DC outputs Voltage 0 to 18V 0 to 36V 0 to 72V Current 5A 3A 1.5A Power(max) 90W 108W 108W Line Regulation Voltage 0-3.999V: 0.01% + 3mV 0-3.999V: 0.01% + 3mV 0-3.999V: 0...
Page 7 - Current
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 5 1.3 Features 1. LCD display with back light. 2. Number keypad and rotary knob. 3. Maximum output voltage limitation. 4. Maximum output power limitation. 5. 10 parameters storage. 6. Can be series / parallel connected ...
Page 8 - power supply
3600 Series Programmable Power Supply VERSION 2.0 2004.6 6 3600 SERIES USER MANUAL 0~9: The number keys Store: Save the current setting value Recall: Read the saved setting value Menu: The menu operation key OUT ON/OFF: Enable/disable the output Enter: The confirmation key V-set: The output voltage ...
Page 10 - Chapter 2 Operation; General operation
3600 Series Programmable Power Supply VERSION 2.0 2004.6 8 3600 SERIES USER MANUAL Chapter 2 Operation 2.1 General operation 1. Connect the power supply with PC 2.2 Function introduction 2.2.1. Main functions 1. Set up voltage 2. Set up current 3. Enable/disable the output 4. Store parameters 5. Rec...
Page 11 - move the cursor to the first number, second number etc by using “ ”and “ ”
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 9 2.3.1 Set up voltage 3600 series power supply provides two methods to set up the output voltage: by the number keypad and by the rotary knob. Please see the following operation procedure. For example, how to set up th...
Page 12 - the following example.
3600 Series Programmable Power Supply VERSION 2.0 2004.6 10 3600 SERIES USER MANUAL 2.3.2 Set up current 3600 Series power supply can be set up for a constant current or a maximum current, please see the following example. Conditions: voltage=24V, load R=12Ohm, then V/R=2 A, it represents the power ...
Page 13 - it then the output will be changed to OFF status, vice versa.
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 11 it then the output will be changed to OFF status, vice versa. 2.3.4 Store parameters If you often use a voltage and current as 24V and 2A or 12V and 2.3A and etc, you just need to set up the data at the first time an...
Page 14 - The recall operation is as follows:
3600 Series Programmable Power Supply VERSION 2.0 2004.6 12 3600 SERIES USER MANUAL 2.3.5 Recall parameters In the last paragraph, we know that we can store 10 sets of parameters. Also you can recall any one of them. It means that you needn’t to set up again for the usually requirements and it bring...
Page 18 - Chapter 3 System Installation of PowerMS Software; System Installation; continue, otherwise there will be no way to install.; Fig 3-3 The Installation Interface 3
3600 Series Programmable Power Supply VERSION 2.0 2004.6 16 3600 SERIES USER MANUAL Chapter 3 System Installation of PowerMS Software 3. 1 System Installation 3.1.1 Put the disk into the CDROM driver. Then select the setup powerMS and the initial diagram as in Fig. 3-1 will be displayed. Fig 3-1 The...
Page 19 - Fig 3-5 The Installation Interface 5; needed to enter and it is just need to click “NEXT”.; Fig 3-6 The Installation Interface 6
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 17 3.1.5 In Fig. 3-5, users may select the installation type. Generally, select “TYPICAL” and click “NEXT” to continue. Fig 3-5 The Installation Interface 5 3.1.6 In Fig. 3-6, enter the file folder’s name and the defaul...
Page 20 - Explanation:
3600 Series Programmable Power Supply VERSION 2.0 2004.6 18 3600 SERIES USER MANUAL Explanation: 3.2.2 Enter the initial interface as shown in Fig. 3-9. Fig 3-9 The System Start Diagram 3.2.3 Wait for the end of the system initialization and then it will be the main interface as shown in Fig. 3- 10....
Page 21 - Chapter 4 The introduction of main functions
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 19 Select the function item and then the interface as shown in Fig. 4-1 will be displayed. Fig 4-1 The Power Definition Interface Chapter 4 The introduction of main functions 4.1 The Definition of the Power Supply Add: ...
Page 22 - Fig 4-2 System Prompt the restart
3600 Series Programmable Power Supply VERSION 2.0 2004.6 20 3600 SERIES USER MANUAL Fig 4-2 System Prompt the restart Login in the identity of “Manager” and then select the quick icon after the system restarts. The dialogue frame as shown in Fig.4-3 will be displayed. Fig 4-3 COM Port and address se...
Page 23 - Fig 4-6 Communication Failure; default COM port is COM1 and the default POWER address is 0.; Fig 4-7 Normal Communication Fig 4-8 Failure Communication; Select the button and the system will stop the communication.; Start the Communication
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 21 In Fig. 4-5, enter the default address (245) of the power supply and then click “READ”. If testing successfully, the “NEW ADDRESS” and “WRITE” functions will be available. If testing failure, then the new address of ...
Page 24 - POWER ON/OFF Set POWER Control Set; Fig 4-10-2 Selecting Control Instruction; PC CONTROL : ontrolled by PC POWER SELF : Control by power supply; Fig 4-10-1 Select the Control Instruction
3600 Series Programmable Power Supply VERSION 2.0 2004.6 22 3600 SERIES USER MANUAL POWER ON/OFF Set POWER Control Set Fig 4-10-2 Selecting Control Instruction There are two methods to set the voltage range: one is by using the rotary button and the other is by using the keypad (0.004~36.000). If yo...
Page 25 - Fig 4-13 Fig 4-14; tions will be listed.; Fig 4-16 Delete the History Data
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 23 4.9 Query the Report Fig 4-13 Fig 4-14 1) Using the rotary knob: Move the mouse to the icon and then rotate the knob. 2) Using the keypad: Select the “A” button, enter the data and then select the “ENTER” button. Exp...
Page 26 - Explanation: The data range condition must be set.
3600 Series Programmable Power Supply VERSION 2.0 2004.6 24 3600 SERIES USER MANUAL Explanation: The data range condition must be set. 7.) Close: Select “CLOSE” and return to the upper-interface. 1.) Instrument Part Voltage Set Value (Accuracy rate: 5 digits) Common Data: Green Overflowing Data: Red...
Page 27 - Power Supply State Indication
3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 25 Add: 3: represents the POWER address. V: 36: represents the defined voltage max value. A: 3: represents the defined current max value. W: 108: represents the defined power max value. Sending: represents the communica...