3Com 10BASE-2 - Manual

3Com 10BASE-2

3Com 10BASE-2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – Read if initial; When handling modules, 3Com recommends that you always use; LED
  • Page 4 – Ensure that you are properly grounded.; Captive screw
  • Page 5 – Option Module; Troubleshooting the System
Loading the manual

U

NTERMINATED

E

THERNET

10BASE-2 (BNC)
M

ODULE

I

NSTALLATION

G

UIDE

For the LANplex 2500/2016

Module Description

This module contains eight (8) unterminated Ethernet 10BASE-2 ports that
use BNC connectors. I

f a port on this module is at the end of a 10BASE-2

(BNC) segment, you must provide an external 50 Ohm terminator.

When the port is at the end of a segment, using a T connector with a
terminating plug may cause interference with adjacent ports. 3Com
recommends terminating ports with the IT T Pomona Y connector, Model
4896, with a terminating plug on the end, or the IT T Pomona Feed-Thru
Terminator, Model 4119-50. When the port is in the middle of a segment, the
Y connector may be necessary.

Prior to installing the unterminated 10BASE-2 (BNC) module, LANplex
system software revision 7.0.0 or later and LANplex diagnostics software
revision 3.0.2 or later must be installed. A system software revision
supporting this module is available from the 3com BBS, the Internet FTP site
(3Com.ftp.com), or 3Com Forum on Compuserve, or 3Com’s Web site
(http://infodeli.3com.com/infodeli/swlib/switch_files.htm).

For a description of how to configure this module into your network, see
the LANplex documentation set.

Audience

This guide is intended for trained technical personnel only.

Port Status

Unterminated

1

2

3

4

5

6

7

8

Active
Error

Board
Error

R

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Read if initial; When handling modules, 3Com recommends that you always use; LED

Status LEDs The option module contains one Board Error LED, eight port status Active LEDs, and eight port status Error LEDs. Depending on the condition, the port status LED is either Active (green) or Error (yellow). See the table below for a description of the status LEDs. . Safety Information Elec...

Page 4 - Ensure that you are properly grounded.; Captive screw

The LANplex system will automatically reset when a module has been installed with the power on. If you physically change the configuration of the system after defining an IP interface, the port designated for that interface may no longer be valid. You may have to redefine the interface. For informat...

Page 5 - Option Module; Troubleshooting the System

4 To seat the module, firmly push the module forward to engage the module and backplane connectors. You will feel a slight resistance as the connectors engage. CAUTION: If the resistance is too great, the module and backplane connec- tors may not be aligned. Forcing the module forward could damage t...

Other 3Com Models

All 3Com Other